FLT#206, BOS-PQI. (AIRCRAFT PERFORMED AN AIR TURN BACK) 'HYD 3 LO PRESS HAPPENED AT CRZ (23000) QHR WOULD NOT RESET; REMOVED AND REPLACED ACMP 3A HYD PUMP PER AMM 29-12-01. LEAK AND OPS TEST PASS. AC OK FOR SRV.'