What was found
DURING HEAVY MAINTENANCE: CRACK INDICATION ON NOSE FWD FUSELAGE/CROSSBEAM SPLICING FR16 LH HOLE 2, CRACK DIRECTION 2 O'CLOCK, CRACK LENGTH 0.105 INCHES; (RESOLVED ON W/O: 1354689 TASKCARD: NR-00032) PERFORMED REPAIR LOCATED FR 16 LH FRAME LAYER ONLY TO HOLE 2 ON CROSSBEAM JUNCTION AREA IAW DRAWING R53112926 ISSUE E, SHEET 3 AND SHEET 4. A. PINEDA ALL WORK DONE ON AEROMAN NR 2025 - 281925W/O:2025 133/1.