What was found
DURING HEAVY MAINTENANCE: CRACK INDICATION ON FRAME 16 LH SIDE IN OPEN FASTENER HOLE H2 AT CROS SBEAM SPLICING AREA, CRACK DIRECTION IS 12 OCLOCK, CRACK DEPTH IS 0.11 2 INCH, AT FWD GALLEY AREA (1 EA); PERFORMED PERMANENT REPAIR ON FRAME 16 LH SIDE HOLE H2 AT CROSSBEAM SPLICING AREA IAW REPAIR DRAWING RR53112926 SHEET 3 TABLE 1.