What was found
DURING HEAVY MAINTENANCE: CRACK INDICATION FOUND ON LOWER INB HOLE OF FR 68 LH DOOR STOP FITTING Ñ1. CRACK DIRECTION 5 AND 11 OCLOCK. CRACK D= 0.160 INCH; (RESOLVED ON W/O: 1404606 TASKCARD: NR-00036) PERFORMED PERMANENT REPAIR ON FR68 LH AT LOWER INBOARD HOLE OF DOOR STOP FITTING #1 IAW SRM 53-41-12-300-008 FIG 002 (SHEET 1/2) FIGURE 003 (SHEET 1) AND IAW SRM 53-41-12-300-010 STEP 2.A. REPAIR IS CATEGORY B INSPECTION THRESHOLD FROM TIME OF ADL/REPAIR EMBODIMENT 24500 FC, SUBSEQUENT INSPECTION AT INTERVALS 10700 FC (FH NOT RELEVANT) INSPECTION METHOD HFEC (REFER TO NTM 51-10-08) AND ROTOTEST (REFER TO NTM 51-10-01) IAW SRM 53-41-12-205-009 TABLE ALL WORK ACCOMPLISHED ON WO 2025195/1 NR542180 FUR-A320-53-02619.