What was found
DURING HEAVY MAINTENANCE: CRACK INDICATION ON FRAME 68 LH SIDE IN OPEN FASTENER HOLE UPPER INBO ARD AT DOOR STOP FITTING 6 POSITION, CRACK DIRECTION IS 3 OCLOCK, CRACK DEPTH IS 0.095 INCH, AT AFT GALLEY AREA (1 EA); EVALUATED DIAMETER HOLES D1 TO D4 AND FOUND WITHIN LIMITS TO REPAIR IAW SRM 53-41-12-300-008 PERFORMED REPAIR LOC. FRAME 68 LH IN OPEN FASTENER HOLE UPPER INBOARD AT DOOR STOP FITTING 6 POSITION IAW SRM 53-41-12-300-010 THIS REPAIR IS CATEGORY B INSPECTION: HFEC AND ROTOTEST I.A.W A320 SRM 53-41-12-205-009 TABLE 1 THIS PART IS CONSIDERED PSE I.A.W 320 SRM 51-11-12 FUR-A320-53-02680.