What was found
DURING HEAVY MAINTENANCE: DON'T PASS TEST EMERGENCY LIGHT FAULT EPSU 10WL; REMOVED AND REPLACED EPSU FIN 10WL IAW AMM 33-51-38-000-001-A, AMM 33-51-38-400-001-A TOOL USED MILLIOHMETER P/N 97F92003500000 S/N G0002 DUE DATE JUN-19-2026.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING HEAVY MAINTENANCE: DON'T PASS TEST EMERGENCY LIGHT FAULT EPSU 10WL; REMOVED AND REPLACED EPSU FIN 10WL IAW AMM 33-51-38-000-001-A, AMM 33-51-38-400-001-A TOOL USED MILLIOHMETER P/N 97F92003500000 S/N G0002 DUE DATE JUN-19-2026.