What was found
FLT 1107, JFK-LHR (ETOPS). AIR BLEED MX MAINTENANCE MESSAGE AFTER PUSHBACK, I MAINTENANCE MESSAGES DISPLAYED ON ECAM STATUS PAGE OF ECAM SYSTEM DISPLAY 1, FAULTS INDICATED BY AIR BLEED.; (RESOLVED ON W/O: 1469094 TASKCARD: NR-00001 ) C/W TSM 36-11-00-810-993 RAR RELAY 22HV. OPS CHECK SATISFACTORY. THIS CLEARS MDDR 605987. MX4 UPDATED PLACARD REMOVED. REF ITEM #1 LOG PAGE 4470190 FOR GROUND VERIFICATION. ( LP 4470190- EFERENCE MDDR 605987 AIR BLEED CLASS II.; ACCOMPLISHED GROUND VERIFICATION OF APU AIR BLEED PER 36-12-00. GROUND VERIFICATION SATISFACTORY.