What was found
FLT 959, BDL- FLL. N593-FTL-959-BDL-FLL-ODOR EVENT THE PILOT ANNOTATED: ODOR ASSOCIATED WITH FUMES AFTER ENGINE START, TO PWR CLIMB DESCENDING THRU 18,000FT TAXI AND SHUTDOWN. THERE WAS NO PRIOR ODOR EVENTS REPORTED IN THE LAST 30 DAYS. THE ACFT WAS TAKEN OOS. COMPLIED WITH INFO NOTICE 2017-T0151 STEP 1. ISOLATED FAULT TO TYPE 8 DEICING FLUID. FOUND EVIDENCE OF DEICING FLUID ON BELLY OF A/C LEADING UP INTO THE APU INTAKE. PERFORMED INSPECTION OF APU & NO LEAKS NOTED. DECONTAMINATION LEVEL A WAS ACCOMPLISHED IAW AMM 21-00-00-615-802 A/C OK FOR SVC.