What was found
DURING HEAVY MAINTENANCE: CRACK FLOOR STRUCTURE UPPER SECTION CONNECTION LOC FR 66 AT LEVEL STR 23KH AT AFT GALLEY AREA (1EA); REMOVED AND REPLACED FLOOR STRUCTURE UPPER SECTION CONNECTION LOC FR 66 AT LEVEL STR 23LH SIDE AT AFT GALLEY AREA (1EA)IAW A320 SRM 51-72-11, A320 SRM 51-42-11 AND DWG 53474250.TOOL USED DIGITAL BENCH SCALE PN 49WA47 SN 8344371720 DUE DATE 8 FEB 2026 REF AEROMAN WO 2025 413/1 NR 2025-682629 FOR WORK PERFORMED.