What was found
FLT # 933 BOS-SFO (ETOPS). ENG 2 FUEL HEAT SYS DEGRADED ( HEAT SYS DEGRAD CAUTIONS ON ECAM E/WD ). INSTALLED NEW IFPC ON ENG 2 AS PER AMM 73-11-01. OPS TEST GOOD AND NO LEAKS NOTED. MDDR CLEARED , MX-4 UPDATED AND PLACARD REMOVED ,
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FLT # 933 BOS-SFO (ETOPS). ENG 2 FUEL HEAT SYS DEGRADED ( HEAT SYS DEGRAD CAUTIONS ON ECAM E/WD ). INSTALLED NEW IFPC ON ENG 2 AS PER AMM 73-11-01. OPS TEST GOOD AND NO LEAKS NOTED. MDDR CLEARED , MX-4 UPDATED AND PLACARD REMOVED ,