What was found
FLT 2104, BOS-LGW. (ETOPS) FUEL ACT XFR FAULT ( AUTO TRANSFER SYSTEM (ACT) ADDITIONAL CENTER TANK(S) (ACT) ). R & R FUEL PUMP IAW AMM 28-28-51.OPS CHKD GOOD, THIS CLEARS MDDR 619300,MX-4 UPDATED,PLACARD REMOVED.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FLT 2104, BOS-LGW. (ETOPS) FUEL ACT XFR FAULT ( AUTO TRANSFER SYSTEM (ACT) ADDITIONAL CENTER TANK(S) (ACT) ). R & R FUEL PUMP IAW AMM 28-28-51.OPS CHKD GOOD, THIS CLEARS MDDR 619300,MX-4 UPDATED,PLACARD REMOVED.