What was found
DURING HEAVY MAINTENANCE, CRACK INDICATION ON FRAME 36 HORIZONTAL FLOORBEAM VERTICAL RADIUS OF THE BACK SIDE OF THE SPAR VERTICAL STRINGER 3 ZONE 2 CRACK LENGTH IS 0 .380 INCH APPROX, IN FWD CARGO COMPARTMENT (1 EA); ACCOMPLISHED PERMANENT REPAIR OF CRACK DAMAGES ON THE CENTER BOX FRONT SPAR HORIZONTAL BEAMS AT LEVEL FR36, Y254 (VERTICAL RADIUS, ZONE 2) IAW AEROMAN EA 57-0036-26, REV 0 (COVER PLUS PARTS 1 AND 2), AIRBUS RDAF 81801723/003/2026, ISSUE A, EC A26-513-01. MEASURE OF LENGTH CRACK IS 0.380 INCH.PERFORMED HFEC AND ROTOTEST ON AFFECTS AREAS IAW NTM 51-10-08 AND NTM 51-10-01 NO CRACK INDICATION FOUND.