What was found
DURING HEAVY MAINTENANCE, CRACK INDICATION FOUNDS (2EA) ON FLOOR BEAM AREA 2 (Y765) , VERTICAL R ADIUS( ZONE 1 AND ZONE 2) , CRACK LENGHT: 0.670 INCH APPROX AD RELATED TASK CARD NO. A320-57-1178-01; (RESOLVED ON W/O: 1435455 TASKCARD: NR-00055 ) REF WO 2026-241/1. NRC 2026-289717, ACCOMPLISHED REPAIR OF CRACK DAMAGE ON THE CENTER WING BOX FRONT SPAR HORIZONTAL BEAMS AT LEVEL OF FR36 AND Y-765, Y-254, Y254 AND Y765 IAW EA 57-0034-26 REV.0 (COVER PLUS PART 1-2) AND EC A26-475-01 AND RDAF 81798668/013/2026 ISSUE A.