What was found
DURING HEAVY MAINTENANCE, CRACK INDICATION ON FRAME 20 LH SIDE IN OPEN FASTENER HOLE H26 AT CROSSBEAM SPLICING AREA, CRACK DIRECTION IS 12 OCLOCK, CRACK DEPTH IS 0.0 85 INCH, AT FWD GALLEY AREA (1 EA); (RESOLVED ON W/O: 1474396 TASKCARD: NR-00025 ) REF: ARM W/O 2026-252/1 N/R 2026-354995 PERFORMED PERMANENT REPAIR ON FRAME 20 LH SIDE AT CROOSBEAM SPLICING AREA IAW REPAIR INSTRUCTIONS R53112926 ISSUE SHEET 3 AND 6 TABLE 5.