What was found
DURING HEAVY MAINTEANCE, CRACK INDICATION FOUND ON THE HORIZONTAL FLOOR BEAM RADIUS BACKSIDE OF THE FRONT SPAR VERTICAL STRINGER Ñ5 FRAME 36. CRACK L= 0.450 INCH.; REF AEROMAN WO 2026 280/1 NR 2026-346063ACCOMPLISHED PERMANENT REPAIR OF CRACK DAMAGES ON THE CENTER WING BOX FRONT SPAR HORIZONTAL BEAMS AT LEVEL FR36, Y-765 VERTICAL STRINGER 5 IAW AEROMAN EA 57-0050-26 REV 0 (COVER PLUS PARTS 1 AND 2), AIRBUS RDAF 81836121/003/2026, ISSUE A. COMPLETED BY R. PORTILLO 8629922 CHECKED BY RII E. GIRON QC 488.