What was found
DURING HEAVY MAINTENANCE, CRACK INDICATION ON FRAME 36 LH SIDE IN PRESSURE DECK MEMBRANE OPEN FA STENER HOLE 3 INCH O/B FROM Y1292 APPROX.,CRACK DIRECTION IS 12 OCLOC K, CRACK DEPTH IS 0.085 INCH APPROX., IN FWD CARGO COMPARTMENT (1 EA); (RESOLVED ON W/O: 1435456 TASKCARD: NR-00072 ) ACCOMPLISHED THE REPAIR ON THE CRACK FOUND ON THE CENTERING BOX PRESSURE PANEL FR36 LH SIDE ATTACHMENT HOLES I.AW WITH AEROMAN EA 53-0053-26 (COVER AND PARTS 1-7) AND EA 53-0061-26(COVER AND PART 1) RDAF 81816449/003/2026#A AND EC A26-699-01.