What was found
DURING HEAVY MAINTENANCE, ELONGATED CENTER HOLE ENTRANCE AFT POSITION PYRAMID MATING FACE FWD MOUNT ON RH PYLON; (RESOLVED ON W/O: 1477496 TASKCARD: NR-00012 ) FUR-A320-54-03371, REF AEROMAN N/R 2026-432556, PERFORMED DETAIL VISUAL INSPECTION ON CENTER HOLE ENTRANCE AFT POSITION PYRAMID MATING FACE FWD MOUNT ON RH PYLON IAW NTM 51-90-00 AND NO FOUND ELONGATED HOLE ONLY FOUND EXISTING REWORK, MEASURES OF EXISTING REWORK ARE: D1= 0.086 INCH, D2= 0.073 INCH, S1= 0.003 INCH, AND EVALUATED REWORKED AREA AND FOUND WITHIN LIMITS IAW A320 SRM 54-51-18-283-003, STEP 2.A.(3),(D) AND (F), FIGURE 005 54-51-18-283-003 (SHEET 1).