What was found
DURING ACCOMPLISHMENT OF AD 92-22-07 (DC-8 CORROSION PROGRAM) THE FOLLOWING INITIAL INSPECTIONS REVEALED LEVEL 2 CORROSION. AFT ACCY COMPT-FS 1440-1500. FS 1563 LONG 18-34R. FS 1563. FS 1563 LONG 34R. FS 1564 LONG 24L. FS 1563 LONG 18L. FS 1560 LONG 18L ANGLES. FS 1440 LONG 34L-35R. REPAIRED IAW APPLICABLE SRM'S, DWG., ETC. (X)