What was found
DURING ACCOMPLISHMENT OF AD 92-22-07 (DC-8 CORROSION PROGRAM) THE FOLLOWING INITIAL INSPECTIONS REVEALED LEVEL 2 CORROSION. RT CUSP EXTRUSION: FS 600 AT FRAME. FS 1240-1260. FS 879.375 FITTING. FS 1400-AT FRAME. FS 1442-1450 WEB. REPAIRED IAW APPLICABLE SRM'S, DWG., ETC. (X)