What was found
YIP - PER AD 66-04-02 INSPECTION, CENTER DRY BAY LOWER SURFACE, 11.5 INCH LONG SUBSURFACE RP/UT CORROSION/CRACK INDICATION IN PLANK 5 AT 5/6 PLANK JOINT, LWS 37.5-49. ROUTED OUT CRACKED AREA, LWS37 TO LWS49, PER SB620. FABRICATED AND INSTALLED REPAIR PER L-188 SRM 57-2-1, SHEET 25. (M)