What was found
DURING CHECK-C MAINT FOUND CABIN FLOOR SUPPORT CORRODED AT STA 200, RBL 47 IN TO 58 IN. FLOOR SUPPORT CORRODED BEYOND LIMITS. FABRICATED NEW FLOOR SUPPORT PER SPM 6-70-01 PAGE 2 AND PAGE 3, AND DRAWING 9936534. CORROSION TREATED NEW FLOOR SUPPORT PER SRM 51-10-3.