What was found
DURING CHECK-C MAINT IN AFT CARGO COMPT FOUND CORROSION ON AFT END OF RT TIE DOWN TRACK, STA 1322 TO 1212. REMOVED AND REPLACED TRACK PER SRM 51-30-2. INSTALLED PER SRM 51-10-5 AND 51-10-1. TREATED AND PAINTED PER SRM 51-10-30, STA 1322 TO 1212.