What was found
DURING CHECK-C MAINT FOUND FLOOR ATTACH ANGLE CORRODED AT STA 351 TO 446, RBL 8. REPLACED FLOOR SUPPORT WITH NEW PER DRAWING 5936587. REPLACED BOLTS, NUTS AND WASHERS PER SRM 51-30-1. REINSTALLED RIVETS PER SRM 51-30-2.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING CHECK-C MAINT FOUND FLOOR ATTACH ANGLE CORRODED AT STA 351 TO 446, RBL 8. REPLACED FLOOR SUPPORT WITH NEW PER DRAWING 5936587. REPLACED BOLTS, NUTS AND WASHERS PER SRM 51-30-1. REINSTALLED RIVETS PER SRM 51-30-2.