What was found
DURING CHECK-C MAINT IN THE CABIN THE FLOOR SUPPORT WAS CORRODED AT STA 204, LBL 6 INCHES. FABRICATED FLOOR SUPPORT FROM 7075-T6 PER SAMPLE AND PER SPM 6-70-01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING CHECK-C MAINT IN THE CABIN THE FLOOR SUPPORT WAS CORRODED AT STA 204, LBL 6 INCHES. FABRICATED FLOOR SUPPORT FROM 7075-T6 PER SAMPLE AND PER SPM 6-70-01.