What was found
DURING CHECK-C MAINT FOUND T-FITTINGS CRACKED AT STA 1309, BETWEEN LONGERON 15 AND 16, AND ANOTHER BELOW LONGERON 14R AND FWD SIDE OF PYLON SUPPORT WALL. INSTALLED NEW ANGLES PER DRAWING 9912243 WITH FASTENERS PER SRM 51-30-0.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING CHECK-C MAINT FOUND T-FITTINGS CRACKED AT STA 1309, BETWEEN LONGERON 15 AND 16, AND ANOTHER BELOW LONGERON 14R AND FWD SIDE OF PYLON SUPPORT WALL. INSTALLED NEW ANGLES PER DRAWING 9912243 WITH FASTENERS PER SRM 51-30-0.