What was found
DURING CHECK-C MAINT FOUND CORROSION IN FLOOR STRUCTURE AT STA 219, 13 INCHES LBL, 9 IN RBL. FABRICATED NEW ANGLE PER DRAWING 9936535. INSTALLED AND SEALED PER SRM 51-30-02 AND 51-20-0.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING CHECK-C MAINT FOUND CORROSION IN FLOOR STRUCTURE AT STA 219, 13 INCHES LBL, 9 IN RBL. FABRICATED NEW ANGLE PER DRAWING 9936535. INSTALLED AND SEALED PER SRM 51-30-02 AND 51-20-0.