What was found
DURING CHECK-C MAINT FOUND CABIN FLOOR SUPPORT CORRODED AT STA 148 TO 200, LBL 7 INCHES, AND STA 180 TO STA 200, LBL 6 INCHES. INSTALLED NEW SUPPORTS PER SRM 51-30-1. FINISH PER SRM 51-10-3.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING CHECK-C MAINT FOUND CABIN FLOOR SUPPORT CORRODED AT STA 148 TO 200, LBL 7 INCHES, AND STA 180 TO STA 200, LBL 6 INCHES. INSTALLED NEW SUPPORTS PER SRM 51-30-1. FINISH PER SRM 51-10-3.