What was found
DURING CHECK-C MAINT FOUND BULGE IN FUSELAGE SKIN AND RIVET HEAD POPPING ABOVE LONGERON 22, BETWEEN OUTFLOW VALVE AND AFT LAV DUMP. INSTALLED NEW OUTFLOW MOUNT RING PER SPM 5-20-01 AND SRM 51-30-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING CHECK-C MAINT FOUND BULGE IN FUSELAGE SKIN AND RIVET HEAD POPPING ABOVE LONGERON 22, BETWEEN OUTFLOW VALVE AND AFT LAV DUMP. INSTALLED NEW OUTFLOW MOUNT RING PER SPM 5-20-01 AND SRM 51-30-02.