DURING CHECK-C MAINT FOUND CANTED FORMER CRACKED, LOWER END OF STA 1485, OTBD OF STAIR CUTOUT. STOP DRILLED CRACK AND INSTALLED DOUBLER PER 53-01 FIG 2. INSTALLED FASTENERS PER SRM 51-30-5 AND 51-30-2.