What was found
DURING CHECK-C MAINT FOUND PUNCTURE HOLE IN LT WING L/E APPROX 8 INCHES FWD OF FRONT SPAR, 13 INCHES AFT AND OTBD OF NUMBER 1 SLAT ANTI-ICE TUBE ON LT WING L/E. REMOVED ALL DAMAGE AND INSTALLED TYPICAL REPAIR PER SRM 57-06A, PAGE 11, AND SRM 51-01 PARAGRAPH 3, ITEM B1-62 PAGE 2.