What was found
DURING CHECK-C MAINT FOUND CORROSION ON FLOOR SUPPORT AT STA 1155, LBL 23 INCHES TO LBL 44 INCHES. REPLACED WITH NEW PART PER SAMPLE AND SPM 6-70-1 AND DOUGLAS DRAWING 5930544. INSTALLED PER SRM 51-30.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING CHECK-C MAINT FOUND CORROSION ON FLOOR SUPPORT AT STA 1155, LBL 23 INCHES TO LBL 44 INCHES. REPLACED WITH NEW PART PER SAMPLE AND SPM 6-70-1 AND DOUGLAS DRAWING 5930544. INSTALLED PER SRM 51-30.