What was found
DURING CHECK-C MAINT FOUND FLOOR MEMBRANE WAS TORN OUT AND ELONGATED HOLES FOR FASTENERS AT LBL 44 INCHES, STA 1175 TO 1191. INSTALLED MEMBRANE REPAIR PER SRM 53-05, FIG 96.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING CHECK-C MAINT FOUND FLOOR MEMBRANE WAS TORN OUT AND ELONGATED HOLES FOR FASTENERS AT LBL 44 INCHES, STA 1175 TO 1191. INSTALLED MEMBRANE REPAIR PER SRM 53-05, FIG 96.