What was found
DURING CHECK-C MAINT FOUND CORROSION AT STA 1250, LBL 24 INCHES TO LBL 44 INCHES, CABIN FLOOR FRAME. REMOVED AND TREATED CORROSION PER SPM 6-80-01 AND SRM 51-10-3. INSTALLED FLOOR SUPPORT PER SPM 6-70-01 AND SRM 51-30-5.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING CHECK-C MAINT FOUND CORROSION AT STA 1250, LBL 24 INCHES TO LBL 44 INCHES, CABIN FLOOR FRAME. REMOVED AND TREATED CORROSION PER SPM 6-80-01 AND SRM 51-10-3. INSTALLED FLOOR SUPPORT PER SPM 6-70-01 AND SRM 51-30-5.