What was found
DURING CHECK-C MAINT FOUND CABIN FLOOR AT L-1 CABIN DOOR, THE OUTBOARD SUPPORT FOR FLOOR PANEL NUMBER 16 WAS CORRODED. REPLACED SUPPORT PER SPM 6-70-01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING CHECK-C MAINT FOUND CABIN FLOOR AT L-1 CABIN DOOR, THE OUTBOARD SUPPORT FOR FLOOR PANEL NUMBER 16 WAS CORRODED. REPLACED SUPPORT PER SPM 6-70-01.