What was found
DURING CHECK-C MAINT FOUND CORROSION ON TOP OF FLOOR BEAM CAP AT STA 1250 FROM LBL 24 TO LBL 43. REMOVED PART AND REMOVED CORROSION PER SPM 6-80-01. INSTALLED PART PER SRM 51-30-2.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING CHECK-C MAINT FOUND CORROSION ON TOP OF FLOOR BEAM CAP AT STA 1250 FROM LBL 24 TO LBL 43. REMOVED PART AND REMOVED CORROSION PER SPM 6-80-01. INSTALLED PART PER SRM 51-30-2.