What was found
DURING CHECK-C MAINT FOUND TWO STATIC BURN PITS WITH 3 INCH CIRCLE OF LIGHT CORROSION. AREA HAD BEEN GROUND APPROX 0.025 DEEP, LOCATED CENTER OF LAP SEAM, STRINGER 4L AND STA 1223. REPAIRED PER ARA 17864.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING CHECK-C MAINT FOUND TWO STATIC BURN PITS WITH 3 INCH CIRCLE OF LIGHT CORROSION. AREA HAD BEEN GROUND APPROX 0.025 DEEP, LOCATED CENTER OF LAP SEAM, STRINGER 4L AND STA 1223. REPAIRED PER ARA 17864.