What was found
DURING CHECK-C MAINT IN TAIL COMPT RT SIDE BETWEEN STA 1474 AND 1486 STRUCTURAL WEB WAS BROKEN OUTBOARD OF STAIR HYD ACTUATOR. INSTALLED NEW STANDARD STRUCTURAL WEB PER SPM 6-70-01 AND DOUGLAS DRAWING 9911946.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING CHECK-C MAINT IN TAIL COMPT RT SIDE BETWEEN STA 1474 AND 1486 STRUCTURAL WEB WAS BROKEN OUTBOARD OF STAIR HYD ACTUATOR. INSTALLED NEW STANDARD STRUCTURAL WEB PER SPM 6-70-01 AND DOUGLAS DRAWING 9911946.