What was found
FOUND CORROSION AT MAIN CABIN SUB FLOOR BETWEEN STA 157 AND 218 AT SEVERAL PLACES. REMOVED WEB AND FLOOR SUPPORT, FABRICATED WEB AND FLOOR SUPPORT, AND INSTALLED FABRICATED WEB AND FLOOR SUPPORT BETWEEN STA 157 AND 218 IAW B717 SRM 51-70-10.