What was found
CABIN, FUSELAGE STA 160 AT CENTER AREA, FLOOR SUPPORT HAS SURFACE CORROSION. REPLACED FLOOR SUPPORT BRACKET FABRICATED PER REF DWG 9936534, MAT PO 1064860 & 3932140-2400. INSTALLED REF B717 SRM 51-41-01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CABIN, FUSELAGE STA 160 AT CENTER AREA, FLOOR SUPPORT HAS SURFACE CORROSION. REPLACED FLOOR SUPPORT BRACKET FABRICATED PER REF DWG 9936534, MAT PO 1064860 & 3932140-2400. INSTALLED REF B717 SRM 51-41-01.