What was found
UPPER CABIN SUBFLOOR CORRODED AS SEEN FROM E&E COMPARTMENT. CUT OUT DIMENSION 40" X 18" STA 160 TO STA 200 AND REPLACED SUBFLOOR (WEB) PER SRM 51-41-02 & 51-70-10 MATERIAL USED 7075 T6 .032 AND 2024 T3 .040.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
UPPER CABIN SUBFLOOR CORRODED AS SEEN FROM E&E COMPARTMENT. CUT OUT DIMENSION 40" X 18" STA 160 TO STA 200 AND REPLACED SUBFLOOR (WEB) PER SRM 51-41-02 & 51-70-10 MATERIAL USED 7075 T6 .032 AND 2024 T3 .040.