What was found
DURING C-CHECK, FOUND FLOOR BEAM UPPER CHORD CORRODED AT BS 967 LBL 28. FABRICATED FLOOR BEAM CAP FROM 1505-100617-7075 T3 16 INCHES BY 2 INCHES IAW B 737 SRM 53-10-9. FABRICATED ANGLE REPAIR FROM 7075.0 .071 INCH 22.50 INCHES BY 1.50 INCHES BY 1 INCH. FABRICATED REPAIR ANGLE NR 2 FROM 7075-0 .063 INCH 26 INCHES BY 2 INCHES BY 1 INCH. FABRICATED STRAP FROM 7075-T6 .071 INCH 27 INCHES BY 1 INCH IAW B 737 SRM 53-10-9. FABRICATED STRAP NR 2 FROM 7075 T6 .063 INCH 22.50 INCHES BY 1 INCH IAW B 737 SRM 53-10-9. INSTALLED IAW B 737 SRM 53-10-9. (X)