Service difficulty reports
1,771,708 reports of malfunctions and defects, newest first. Air carriers must report; general aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA2026010856257Angle · corrodedRBL 32 FWD CARGO TRANSITION ANGLE HAS CORROSION FROM 500A-500B. REMOVED DAMAGE AND WAS FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-1. REMOVED AND REPLACED ON TTG8Q019M80A.SDR SWAA2026010856259Angle · corrodedRBL 32 FWD CARGO TRANSITION ANGLE HAS CORROSION FROM 5000F-500G. REMOVED DAMAGE AND FOUND TO BE OUT OF LIMITS ER SRM 53-00-53-1A-1. REMOVED DAMAGE AND WAS FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-2. REMOVED AND REPLACED ON TTG8Q019M80A.SDR SWAA2026010856248Angle · corrodedRBL 32 FWD CARGO TRANSITION ANGLE HAS CORROSION FROM 500G-500H. REMOVED DAMAGE AND WAS FOUND TO BE OUT OF LIMITS I.A.W. SRM 53-00-53-1A-1. REMOVED DAMAGE AND WAS FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-2. REMOVED AND REPLACED ON TASK CARD TTG8Q019M80SDR SWAA2026010856260Angle · corrodedRBL 32 FWD CARGO TRANSITION ANGLE HAS CORROSION FROM 500H-500I. REMOVED DAMAGE AND FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-1. REMOVED DAMAGE AND WAS FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-2. REMOVED AND REPLACED ON TTG8Q019M80A.SDR SWAA2026010856250Angle · corrodedLBL 32 FWD CARGO TRANSITION ANGLE HAS CORROSION FROM 500A-500B. REMOVED DAMAGE AND WAS FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-1. REMOVED DAMAGE AND WAS FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-2R-5. REMOVED AND REPLACED ON TASK CARD TTG8Q019M80W.SDR SWAA2026010856252Angle · corrodedLBL 32 FWD CARGO TRANSITION ANGLE HAS CORROSION FROM 500E-500F. REMOVED DAMAGE AND WAS FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-1. REMOVED DAMAGE AND WAS FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-2R-5. TO BE REMOVED AND REPLACED ON TASK CARD TTG8Q019MSDR SWAA2026010856253Angle · corrodedLBL 32 FWD CARGO TRANSITION ANGLE HAS CORROSION FROM 500F-500G. REMOVED DAMAGE AND WAS FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-1. REMOVED DAMAGE AND WAS FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-2R-5. TO BE REMOVED AND REPLACED ON TASK CARD TTG8Q019M80SDR SWAA2026010856254Angle · corrodedLBL 32 FWD CARGO TRANSITION ANGLE HAS CORROSION FROM 500G-500H. REMOVED DAMAGE AND WAS FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-1. REMOVED DAMAGE AND WAS FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-2R-5. TO BE REMOVED AND REPLACED ON TASK CARD TTG8Q019MSDR SWAA2026010856255Angle · corrodedLBL 32 FWD CARGO TRANSITION ANGLE HAS CORROSION FROM 500H-500I. REMOVED DAMAGE AND WAS FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-1. REMOVED DAMAGE AND WAS FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-2R-5. TO BE REMOVED AND REPLACED ON TASK CARD TTG8Q019MSDR SWAA2026010756246Angle · corrodedRBL 32 FWD CARGO TRANSITION ANGLE HAS CORROSION FROM 500D-500E. REMOVED DAMAGE AND WAS FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-1. REMOVED AND REPLACED ON TASK CARD TTG8Q019M80A.SDR SWAA2026010756247Angle · corrodedRBL 32 FWD CARGO TRANSITION ANGLE HAS CORROSION FROM 500E-500F. REMOVED DAMAGE AND WAS FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-1. REMOVED AND REPLACED ON TTG8Q0156FTY.SDR SWAA2026010756249Angle · corrodedLBL 32 FWD CARGO TRANSITION ANGLE HAS CORROSION FROM 500-500A. REMOVED DAMAGE AND WAS FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-2. REMOVED DAMAGE AND WAS FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-2. LOCATED; DRILLED, AND FABRICATED PARTS PER SRM 5SDR SWAA2026010756258Angle · corrodedRBL 32 FWD CARGO TRANSITION ANGLE HAS CORROSION FROM 500B-500C. REMOVED DAMAGE AND WAS FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-1. REMOVED AND REPLACED ON TASK CARD TTG8Q0156FTY.SDR DALA2026010709569Spar Web · not reportedFOUND EXISTING REPAIR AT LT PYLON STRUT FORWARD MID SPAR WEB AT NSTA 221.25. REPAIR DESCRIPTION DETAILED IN THE COMMENTS SECTION OF ER/A 585425-14. (1374601)SDR DALA2026010709568Floorbeam · crackedFOUND CABIN FLOORBEAM LOWER SURFACE CRACK AT BS 1439 AND LBL25. CRACK AREA AT STA 1439 LBL25 REPAIRED AS PER PRI 630972-14 REV 0. (1374435)SDR DALA2026010600110Snubber · out of toleranceOUT OF LIMITS EXTENSION PIN ON SNUBBER AT R1 DOOR. R1 SNUBBER WAS REPLECED PER SERVICIABLE R1 SNUBBER PER B757-200 AMM 52-11-10 AND DOOR R1 WAS REMOVED/INSTALLED PER B757-200 AMM 52-11-01. (1375847)SDR DALA2026010509566Web · corrodedAFTER REMOVAL OF INBOARD RT SEAT TRACK, SUB FLOOR SKIN IS CORRODED. REPAIRED SUB FLOOR MEMBRANE IAW SRM 53-00-55 (1375171)SDR DALA2026010509564Fuel Sys · leakingFUEL LEAK FOUND DURING INSPECTION OF THE LT WING AFT LOWER SKIN AT XRS=164. REPAIRED PER ERA 629418-14AD (1375656)SDR DALA2026010500063Skin · not reportedDTA MONITOR INSPECTION LOG REF ERA 631258-14. FUSELAGE SKIN, BS 590 - 630, STR 14L-19L. EXISTING REPAIR. REF ERA 631258-14AD. (1375734)SDR DALA2026010500062Snubber · out of toleranceOUT OF LIMITS EXTENSION PIN ON SNUBBER AT L2 DOOR. CORRECTIVE ACTION: SUMMARY OF NRC 00134, THE L2 SNUBBER WAS REMOVED AND REPLACED PER B757-200 AMM 52-11.SDR DXTA2026010206357Actuator · faultyPITCH TRIM JAM DURING TAKE-OFF. PRIMARY PITCH TRIM WOULD NOT ACTUATE NOSE DOWN WHILE BEING PRESSED CONSTANTLY FOR AT LEAST 5-6 SECONDS AFTER TAKE-OFF. A LOUD CLUNK/THUD NOISE WAS HEARD. SECONDARY TRIM WAS SELECTED AND USED TO REGAIN PITCH CONTROL. AN IMMEDIATESDR DXTA2026010206358Engine · faultyUPON CLIMBING THROUGH APROX 2500', RECEIVED A E2 OIL LOW PRESSURE CAS MESSAGE. ADVISED NEEDED TO RETURN TO AIRPORT. ABOUT A MINUTE LATER DETECTED A BURNING ODOR WHICH WAS SHORTLY FOLLOWED BY SMOKE FILLING THE CABIN. DECLARED AN EMERGENCY & ADVISED RETURNING. RSDR CALA2026010412647Skin · damagedAS PER C/R REPLACE THE FWD CARGO DOOR INNER SKIN. REMOVED AND REPLACED FWD CARGO DOOR SKIN PER SRM 51-40-02-0G-0 AND DWG#143A6110SDR DALA2026010509563Skin · damagedHORIZONTAL STAB, RIGHT OTBD LEADING EDGE DAMAGED. HORIZONTAL STAB, RIGHT OTBD LEADING EDGE REMOVED AND SENT TO D384/MSP FOR DISPOSITION.SDR AALA202601052692Floorbeam · crackedAIRCRAFT IN BASE MAINTENANCE: CRACK IN PASSENGER CABIN FLOORBEAM AT BS 540, LBL 3. REPLACED FLOORBEAM PER AARD 51-00-05-1.SDR AALA202601057147Floorbeam · crackedAIRCRAFT IN BASE MAINTENANCE: CRACK IN PASSENGER CABIN FLOOR STRUCTURE FLOORBEAM AT BS 540, RBL 3. REPLACED FLOORBEAM PER AARD 51-00-05-1.SDR DALA2026010400047Engine · contaminatedDIRTY SOCK SMELL BRIEFLY AT 10000 FT DURING CLIMB DIRTY SOCK SMELL RETURNED BRIEFLY AT 25000 FT DURING DECENT AT 10000 FTB WITH ENGINES AT IDLE SMELL RETURNED GOT STRONG UNTILL POWER INCREASED ABOVE IDDLE, THEN DISSIPATED SMELL NOTED IN FWD GALLEY - NO SMELL MSDR IPXA2025123069701Skin · damagedFUSELAGE DAMAGE FROM PACKAGE CONTAINER AT FRAME 54 STATION 3354 LEFT SIDE PAST HYD. SERVICE DOOR. VERIFY DAMAGE AND REPORT FINDINGS TO SDF LIAISON ENGINEERING PRIOR TO STARTING INITIAL CUTOUT. FOUND 24€? LONG DENT FWD AND AFT OF FRAME 54.2. WIDTH OF DENT MEASSDR CALA2026010212636Diaphragm · damagedLEFT WING DRY BAY STRUCTURE, RIB 6 - 6B, CLOSING PANEL AND DIAPHRAGM WERE REPLACED AT MLB. REPAIR IS EXPECTED TO BECOME A PERMANENT SOLUTION WITH NO SUPPLEMENTAL INSPECTION REQUIREMENTS. ACCOMPLISH PERMANENT REPAIR ACTION IAW PART 3 OF THE LATEST REVISION OF ESDR CALA2026010212627Spring · faultedLEFT MAIN GEAR AFT UPLOCK SPRING COMPLETLY DETACHED FROM AC. SEARCH LANDING GEAR AND SUROUNDING AREA NO SPRING FOUND AND NO ADDITIONAL DAMAGE NOTED. SPRING PLACED ON DEFFERAL NO FURTHER ACTION NOT REQUIRED.LT MLG DOWN LOCK SPRING IS MISSING LT MLG MISSING AFTSDR CALA2026010212606Switch · faultedENG 2 FUEL FILTER BYPASS LIGHT ON ENG SLOW TO RESPOND AT IDLE POWER SETTING, ENG 2 FUEL FILTER BYPASS CAME ON DURING APPROACH AT AROUND 14,000. FT. IDLE POWER SETTNGS WERE SLOW TO RESPOND. N1/N2 IDLE FLUCTUATING AROUND 30-35. FLUCTUATION ON N1 ONLY, ON ENG 2 RSDR CALA2026010212585Valve · faultedFLIGHT DECK BECAME VERY COLD. LT PACK SHOWING 0 DEGREES. EMER PROC PERFORMED.CREW DEBREIF. CREW REPORTS SEVERSLMHOURS AT CRUISE NOTICED FLT DECK GETTING COLDER, ATTEMPTED TO INCREASE TEMP THROUGHNTEMP CONTROL DIALS WITH NO CHANGE. FOLLOWED QRH DIRECTION TO CHESDR CALA2026010212584Girt Bar · out of positionR1 GIRT BAR IS DRAGGING REMOVED DOOR 1R SLIDE AND PACKED ZEE FOLD AND INSTALLED AFFECTED SLIDE IAW AMM 26-66-01/401 FLAGGING RII. ACCOMPLISHED RII INSPECTION OF DR 1R SLIDE INSTALLATION PER GMM 09-25-05 AND AMM 25-66-01.SDR CALA2026010212583Warning Light · malfunctionedCARGO COMPARTMENT LIGHT DOES NOT GO OFF FORWARD. REPEAT GRIPE. FWD CARGO DOOR VERIFIED CLOSED BEFORE PUSH BUT CAME ON DURING T/O ROLL TOMC REQUEST. PLEASE DEACTIVATE FWD CARGO DOOR INDICATION SWITCH PER MEL CARD 52010 AND AMM 52-71-31-000-801. UPDATE EXISTINSDR CALA2026010212582Strap · unsecureL2 ENTRY DOOR HAS STRAP HANGING DOWN FROM BOTTOM . RESECURED L2 DOOR EMERGENCY ESCAPE SLIDE STATIC LINE IN THE SLIDE STATIC LINE STORAGE POCKET IAW AMM 25-66-0. PERFORMED RII INSPECTION OF STATIC LINE STOWAGE. REMOVAL OF DEACTIVATION PINS. SAFETY AND SECURISDR CALA2026010212578Light · malfunctionedSIDE LIGHT AT SEAT 21A IS FLICKERING. 21A IS EMERGENCY EXIT ROW COMPLIED WITH MEL 3302B. PERFORMED EMRGY LIGHT TEST, ALL EMERGY LIGHTS WORK NORMAL. COLLARD CB 12E ON PANEL P92. LEFT SIDE LIGHT. COLLARD CB 12E AT PANEL P92 WAS DONE IAW AMM 33-20-00-710-804-001SDR DXTA2026010206355Check Valve · faultedAFTER SELECTING GEAR UP ON TAKEOFF, WE RECIEVED A GEAR DISAGREE CAS MESSAGE. THE TWO MAIN GEAR SHOWED UP AND LOCKED HOWEVER THE NOSE GEAR DISPLAYED AN AMBER DN INDICATION WITH THE GEAR HANDLE IN THE UP POSITION. QRH PROCEDURE WAS COMPLIED WITH AND RESULTED WITSDR R61A2025122900550Windshield · crackedFO WINDSHIELD CRACKED ON APPROACH AND WINDSHIELD HEATER 2 EICAS MSG. DECLARED EMERGENCY, LANDED WITHOUT INCIDENT. REPLACED FO WINDSHIELD.SDR AALA202601021118Unknown · odorAIRCRAFT IN BASE MAINTENANCE: AN EMERGENCY WAS DECLARED AND THE AIRCRAFT DIVERTED TO ELP DUE TO THE FLIGHT CREW REPORTING THAT THE FLIGHT ATTENDANTS WERE EXPERIENCING HEADACHES DUE TO A SMELL FROM THE AFT GALLEY. THE AIRCRAFT LANDED SAFELY AT ELP WHERE IT TAXISDR HNAA2025123000867Fuel · leakingSEVERE TURBULENCE ON APPROACH. C/W SEVERE TURBULANCE INSPECTION IAW AMM 05-50-27. DURNING SEVERE TURBELANCE INSPECTION FOUND FUEL SEEPAGE ON RT WING,RIB 9,CREV 1 AND MULTIPLE SCREWS ON LWR LEADING EDGE. INSPECTED INTERNAL FUEL TANK RH LEADING EDGE AT RIB7. SDR AALA202601018483Apu · odorAIRCRAFT WAS GROUNDED: DIRTY SOCK FUMES BELOW 10,000 IN ALL PHASES OF FLIGHT. ESPECIALLY DOMINANT DURING POWER CHANGES, IDLE TO ADVANCED SETTINGS. MAINTENANCE DETERMINED APU WAS SOURCE OF ODOR, APU WAS CHANGED PER SOF J/C'S AND ACCOMPLISHED ON J/C26L3049003.SDR SWAA2025123156425Flashlight · inoperativeAFT RIGHT FA FLASHLIGHT INOPERATIVE. PERFORMED OPS TEST PER AMM 25-64-00. FOUND OK.SDR SWAA2025123156725Slide · out of adjustFWD GALLEY DOOR SLIDE PARTIALLY OUT OF BOX. INSTALLED THE FWD SERVICE DOOR SLIDE ASSEMBLY IAW MT 725-61-06.SDR SWAA2025123156393Cover · looseRIGHT EMERGENCY LIGHT COVER LOOSE. SECURED THE EMERGENCY EXIT LIGHT COVER IAW SIP.SDR SWAA2025123156405Battery Pack · dischargedLEFT EMERGENCY EXIT SIGN INOPERATIVE. CHARGED THE BATTERY PACKS IAW AMM 33-51-06 AND OPS CHECKED GOOD.SDR DXTA2025123106347Battery Pack · inoperativeEMERGENCY LIGHT ABOUT MED INOP. ALSO FORWARD FACING EMERGENCY LIGHT ON LEFT SIDE IS FLICKERING. PLEASE SEE PHOTO/ VIDEO CORRECTIVE ACTION: REMOVED #1 E-BATT PN 6430028-1 SN F24-11024 AND INSTALLED A NEW BATT PN 6430028-1 SN K2511703. REMOVED #4 E-BATT PN 64300SDR JJBA20251231039Thrust Reverser · damagedLEFT ENGINE THRUST REVERSER FWD OUTBOARD EDGE DAMAGED AND TORN. THE REPAIR HAS BEEN COMPLETED.SDR JJBA20251231038Skin · dentedAPU COWLING LOWER SKIN FOUND WITH TWO PROTRUSIONS. DENTS 1 AND 2 WERE REPAIRED. DENT 3 IS FREE OF SHARP EDGES AND THERE ARE NO SIGNS OF MISSING OR PULLED FASTENERS. DETAILED VISUAL INSPECTION WAS PERFORMED AND NO DAMAGED WERE FOUND.SDR DALA2025123109555Cradle · damagedSEVERAL EMERGENCY LIGHTS ON RT SIDE OF A/C INOP. R & R BATTERY CRADLE (BPS) PER B767-300 WDM 33-51-31 (7880118)SDR ASAA2025122963464Battery Pack · no testL2 DOOR EMERGENCY EXIT SIGN BATTERY PACK FAILS CAPACITY CHECK PER TC 33-055-00. GROUNDED - YES. REPLACED EMERGENCY LIGHT BATTERY PACK FOR L2 DOOR EMERGENCY EXIT SIGN PER AMM 33-51-06. BATTERY PACK CHECKS GOOD.