Service difficulty reports
1,771,708 reports of malfunctions and defects, newest first. Air carriers must report; general aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR AALA202506135423Slide Raft · bulgedAIRCRAFT WAS GROUNDED: A/C LEFT FWD MAIN DOOR SLIDE WILL NOT ARM. MAINTENANCE REPLACED L1 DOOR SLIDE RAFT PER J/C 26L00025011.SDR JJBA20250613012Lamp · inoperativeINTERIOR EMERGENCY LIGHS ABOVE SEATS 18A AND 18CD INOPERATIVE. REMOVED AND REPLACED BOTH BULBS. OPS CHECK SAT.SDR AALA202506131457Attach Angle · crackedAIRCRAFT IN BASE MAINTENANCE: CRACK IN WING CENTER SECTION REAR SPAR VAPOR BARRIER UPPER ATTACH ANGLE AT STA 663, LBL 8. REPAIRED PER SRM 57-10-10-2R-5.SDR AALA202506135841Attach Angle · crackedAIRCRAFT IN BASE MAINTENANCE: CRACK IN WING CENTER SECTION REAR SPAR VAPOR BARRIER UPPER ATTACH ANGLE AT STA 663, RBL 8. REPAIRED PER SRM 57-10-10-2R-5.SDR CALA2025061305546Indicator · faultyTE FLAP DISAGREE AT APPROX 1000FT. FLAPS STUCK AT 25.. INITIATED GO AROUND. CREW REPORTED THAT WHEN FLAP HANDLE WAS MOVED TO 30 THE FLAPS REMAINED AT 25 WITH TE FLAP DISAGREE MESSAGE. AFTER THEY MOVED THE HANDLE BACK TO 25 PER CHECKLIST MESSAGE WENT AWAY. TROSDR CALA2025061305539Mount · corroded(SDR) (19-5305-1-2068): CABIN FLOOR GALLEY MOUNT FITTING HAS COR ROSION STA 1685, CENTER LINE - "1". ESFR COMPLETED. EVALUATED CORROSION ON CENTER GALLEY MOUNT FITTING AND FOUND NO SRM ALLOWABLE LIMITS. REMOVED AND REPLACED CENTER GALLEY MOUNT FITTING 415N4002SDR CALA2025061305528Potable Water · odorPLANE POTABLE WATER FROM ALL GALLEYS TASTE/SMELL STRONG CLORINATION AND DETERGENT. PAX COMPLAINT FLUSHED POTABLE WATER SEVERAL TIMES PER AMM 38-10-00-170-003, OK TO CONTINUE.SDR HALA20250612178Thermocouple · damagedETOPS - WHILE PERFORMING HP-IP BORESCOPE INSP TC: A2010-07-09-PART01 FOUND TERMINAL ON VENT TUBE OVERHEAT THERMOCOUPLE DAMAGED. REMOVED AND REPLACED VENT TUBE OVERHEAT THERMOCOUPLE PER AMM 77-22-11-000-801-A. CK GOOD OK FOR SVCSDR DALA2025061304480Actuator · trippedSHIP 3048 - MISC/DE - DUE TO SLATS LOCKED OUT AT ZERO (F/CTL SLATS FAULT ECAM WARNING). CORRECTIVE ACTION: FOUND RIGHT WING #4 SLAT ROTARY ACTUATOR (6087CM) TRIPPED. REPLACED SAME. OK FOR SERVICE. (LP 7481606)SDR ASAA2025061158661Lens · missingSIDEWALL EXIT/SALIDA LT LENS MISSING AT ROW 16 ABC. GROUNDED - YES. REPLACED LT LENS ON EXIT/SALIDA LT AT ROW 16 ABC SIDEWALL. REF AMM 33-51-01. OPS CHK GOOD.SDR DALA2025061204479Servo Control · excess playSHIP 3162 EMPENNAGE RUDDER YELLOW SERVO CONTROL HAS PLAY, IT HAS 11,40MM. CORRECTIVE ACTION: PERFORMED FUNCTIONAL CHECK OF RUDDER SERVO CONTROL AND HINGE LINE BEARINGS FOR EXCESSIVE PLAY I.A.W A319 AMM TASK 27-24-00- 200-803-A. REE PLAY WAS 8,02MM REV 131 DATESDR DALA2025061204470Servo Control · excess playSHIP 3162 EMPENNAGE RUDDER GREEN SERVO CONTROL HAS PLAY, IT HAS 12,18MM. CORRECTIVE ACTION: PERFORMED FUNCTIONAL CHECK OF RUDDER SERVO CONTROL AND HINGE LINE BEARINGS FOR EXCESSIVE PLAY I.A.W A319 AMM TASK 27-24-00- 200-803-A. FREE PLAY WAS 8,33MM REV 131 DATESDR DALA2025061204469Servo Control · excess playSHIP 3162 EMPENNAGE RUDDER BLUE SERVO CONTROL HAS PLAY, IT WAS 11,30MM. CORRECTIVE ACTION: PERFORMED FUNCTIONAL CHECK OF RUDDER SERVO CONTROL AND HINGE LINE BEARINGS FOR EXCESSIVE PLAY I.A.W A319 AMM TASK 27-24-00- 200-803-A. FREE PLAY WAS 8,20MM REV 131 DATEDSDR SWI2025F00725Duct · warning messageANTI-ICE DUCT WARNING MESSAGE. LEFT LEADING EDGE RED ON SYNOPTIC PAGE. (FLIGHT 6484 - FILED CLOSED)THIS DISCREPANCY WAS TRANSFERRED TO CAMP ITEM 30299219 WITH THE FOLLOWING CORRECTIVE ACTION: "REVIEWED HISTORY AND FOUND WING ANTI-ICE LOOP B DEFERRED, SEE EAML SDR SWI2025F00724Element · warning messageL BLEED DUCT WARNING MESSAGE AFTER COWLS TURNED ON. BLEEDS CLOSED AUTOMATICALLY, PRESSURIZATION LOST. QRH COMPLIED WITH. (FLIGHT 6484 - FILED CLOSED)THIS DISCREPANCY WAS TRANSFERRED TO CAMP ITEM 30299218 WITH THE FOLLOWING CORRECTIVE ACTION: "INTERROGATED MDC SDR SWIA202506120011Duct · warning messageL SIDE FUSELAGE ANTI ICE DUCT WARNING MESSAGE IN ICING WITH WINGS/COWLS SELECTED ON. ACCOMPLISHED QRH WHICH REMOVED MESSAGE. (FLIGHT 5435 - FILED OPEN)THIS IS CURRENTLY A WORK IN PROGRESSSDR SWAA2025061280284Seat Back · out of adjustSEAT 11B (IN EMERGENCY EXIT ROW) RECLINES.<[01] C/W;[02] ADJUSTED HYDRO-LOCKS TO THE LOCKED POSITION PER AMM 25-22-00SDR SWAA2025061281073Girt Bar · looseFWD ENTRY DOOR CAPTS SIDE GIRT BAR HOLDER LOOSE<[01] ADJ L-1 SLIDE CLIPS AS PER AMM 25-66-01SDR SWAA2025061280619Flashlight · no testFLIGHT DECK EMER FLASHLIGHT SEAL BROKEN AND UNIT WILL NOT TEST<[01] R & R? D FLT DECK EMER FLASHLIGHT BATTERY AND SEAL IAW AMM 25-64-00.SDR SWAA2025061280564Lamp · inoperativeRIGHT EMERGENCY EXIT OVERHEAD LIGHT IS INOP.<[01] RELAMPED PER AMM 33-51-01;[02] VERIFIED RELAMPED PER AMM 33-51-01SDR SWAA2025061280591Battery Pack · failedALL EMERGENCY LIGHTS ASSOCIATED WITH BATTERY PACK (M01676) FAIL TEST<[01] REPLACED EMERGENCY BATTERY PACK (M1676); PERFORMED GOOD TEST PER AMM 33-51-06-960-805;[02] VERIFIED.SDR SWAA2025061281077Sign · detachedMID CABIN OVERHEAD EXIT ROW SIGN DETACHED<[01] RESECURED SIGN OP'S CK GOOD IAW M/M 33-51-01SDR SWAA2025061281091Unknown · odorPLASTIC BURNING SMELL DETECTED BY FA AND PASSENGERS AROUND ROW 5-6 DURING PUSHBACK. COULD NOT FIND SOURCE. RETURNED TO GATE<[01] INSPECTED CABIN AREA FWD CARGO AREAS PER AMM05-51-56 NO SMELLS OUT OF ORDINARY W/#2 ENGINE RUNNING PACKS ON . UNABLE TO DUPLICATE.SDR GTIA2025061238954Megaphone · inoperativeFWD GALLEY MEGAPHONE MISSING KNOB-R/R FWD GALLEY MEGAPHONE IAW AMM 25-65-51 OPS CHECK GOOD A/C OK FOR SVC.SDR GTIA2025061238953Ecs · contaminatedBOTH AFT F/A'S REPORTED DIRTY SOCK ODOR AT TOP OF DESCENT. ROW 19 TO AFT GALLEY. DESCRIPTION OF ODOR/FUMES: TEMPORARY, DIRTY SOCK/MUSTY DRY SMELL. APPARENT CABIN SOURCE: UNKNOWN. AFT CABIN/GALLEY(LAV). NO VISIBLE SMOKE/HAZE. NO MEDICAL ATTENTION REQUIRED.-PERFSDR N6WA2025061211Angle · corrodedCORROSION ON KICK PLATE ANGLE STGR17L-STGR18L AT PAX DOOR. REMOVED AND REPLACED NEW KICK PLATE ANGLE ON STGR17L-STGR18L AT PAX DOOR IAW CRJ SRM 51-42-06SDR N6WA2025061210Access Panel · corrodedCORROSION ON SIDE PANEL AT ACCESS PANEL 832JL ON PAX DOOR. REMOVED AND REPLACED SIDE PANEL AT ACCESS PANEL 832JL ON PAX DOOR IAW CRJ SRM 51-42-06SDR IPXA2025061169907Power Supply · dischargedEMER LT BAT 1 LO LEVEL 1 MESSAGE DURING PREFLIGHT OF EMERGENCY LIGHT SYSTEM REVERSED DMP. REMOVED AND REPLACED EMERGENCY LIGHTING BATTERY POWER SUPPLY IAW MD11 AMM 33-51-01. OPS CHECK GOOD, MESSAGE DID NOT REAPPEAR. THIS CLEARED MEL, PLACARD REMOVED.SDR IPXA2025061164148Plate · missingATB GEAR DOORS EICAS MESSAGE. CYCLED FROM OFF TO UP PER QRH.MESSAGE CLEARED. UPON TROUBLESHOOTING FOUND LFT MAIN GEAR DOOR PROXIMITY SWITCH S10242 DAMAGED. R & R€™D S10242 IAW MM 32-61-02-201, SYS OPS CK€™S NORMAL.SDR IPXA2025061258372Evas Unit · abnormal**SUPPLEMENTAL SDR** CAPTAINS EVAS TEST TOOL MISSING. INSTALLED EVAS TOOL FOR CAPTAIN'S EVAS IAW AMM 25-69-00. OPS CHECK GOOD. REMOVED FROM NEF.SDR N6WA2025061209Angle · corrodedCORROSION AT PAX DOOR STGR18 MID CAP ANGLE. REMOVED AND REPLACED CAP ANGLE ON PAX DOOR STGR18 IAW CRJ SRM 51-41-02SDR N6WA2025061207Floor Support · corrodedRH FLOOR SILL BETWEEN FS280-FS319.7 HAS CORROSION. REMOVED AND REPLACED RH FLOOR SILL BETWEEN FS280-FS319.7 IAW CRJ SRM 51-42-06 AND SRM 51-42-13SDR N6WA2025061206Drag Angle · crackedPAX DOOR STAIR AFT DRAG ANGLE IS CRACKED. PERFORMED REPAIR ON PAX DOOR STAIR AFT DRAG ANGLE IAW CRJ SRM 51-11-04SDR N6WA2025061205Floorbeam · corrodedLH FLOOR BEAM AT FS280 CORRODED. REMOVED AND REPLACED LH 280 FLOOR BEAM IAW CRJ SRM 51-42-06, SRM 51-42-13 AND SRM 51-42-21SDR QXEA2025061200255Shear Tie · corrodedSHEAR TIE CORRODED AT FR78 STR28L-27L. BLENDED OUT SHEAR TIE AT FR78 STR28L-27L BE OUT LIMITS IAW SRM 51-75-16. REPLACE SHEAR TIE IAW SRM 51-40-08.SDR N6WA2025061204Stringer · corrodedSTGR27 CORRODED AT FS280.00-FS295.00. REMOVED AND REPLACED STRIGER 27 BETWEEN FS280-FS295 IAW CRJ SRM 51-42-06 AND SRM 51-42-21SDR N6WA2025061203Floorbeam · corrodedCOCKPIT FLOOR SUPPORT ANGLE AT FS280 HAS CORROSION. REMOVED AND REPLACED COCKPIT FLOOR SUPPORT ANGLE AT FS280 IAW CRJ SRM 51-42-06SDR KCSA2025061130Slide · dislodgedON OPENING L1 DOOR SLIDE CAME OUT OF PACK BUT DIDN'T DEPLOY. L1 DOOR SLIDE REMOVED FROM AIRCRAFT IAW B777 AMM 25-66-01. TRANSFERRED TO DMI 100258399 B777 MEL 52-11-1-2 CAT C, DUE 6/21/25 PLACARDS INSTALLED. 100258409- SLIDE PARTIALY DEPLOYED REQUIRES EPAS CHANSDR N6WA2025061202Floor Support · corrodedAFT CARGO DOOR FLOOR SILL IS CORRODED. REMOVED AND REPLACED AFT CARGO DOOR FLOOR SILL IAW CRJ SRM 51-42-06, 51-42-21 AND 51-42-13.SDR SIMA20250611001Flap System · malfunctionedFLAP FAIL ON APPROACH EMERGENCY DECLARED T/S PER FIM 27-51-00. FOUND TO BE TRANSITORY CONDITION OF THE SLAT/FLAP ACE. PERFORMED OPS CHECK. OPS CHECK GOOD. NO FURTHER DEFECTS NOTED.SDR SIMA20250611004Flashlight · inoperativeCA FLIGHTDECK EMERGENCY FLASHLIGHT NOT WORKING. FLIGHT CREW PLACARDED CA EMERGENCY FLASHLIGHT NOT CHARGING REF MEL 25-52 AUTH 060599M-C PIC 218401. PERFORMED OPC ON CA EMERGENCY FLASHLIGHT ASSY. OPC GOOD IAW AMM 33-51-00. MEL RESTORED, NO FURTHER DEFECTS NOTEDSDR SIMA20250611002Door · bindingGATE AGENT HAD DIFFICULTY OPENING L1 CABIN DOOR. VENT FLAP OPENED FINE. GATE AGENT SAID THEY HAD TO LIFT DOOR UP TO COME OUT AND OPEN. LUBRICATED L1 DOOR ROLLERS OCK GOOD IAW AMM CH 52-11-00SDR SIMA20250611003Sign · detachedAFT PAX DOOR SURROUND EMERGENCY EXIT IDENTIFIER SIGN PARTIAL INOP. REMOVED AND REPLACE AFT. PAX-DOOR SURROUND EMERGENCY EXIT IDENTIFIER SIGN IAW EMB 175 AMM 33-50-15, OPS CHECK GOOD.SDR AALA202506126408Battery · no testAIRCRAFT WAS NOT GROUNDED: BATTERY FAULT FOR EMERGENCY POWER SUPPLY UNIT 14WL DISPLAYED DURING SYSTEM TEST. MAINTENANCE REPLACED BATTERY FOR EMERGENCY POWER SUPPLY UNIT 14WL AND ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK PER AMM 33-51-38 WITH NO FAULTS NOTESDR AALA202506128372Battery · no testAIRCRAFT WAS NOT GROUNDED: BATTERY FAULT FOR EMERGENCY POWER SUPPLY UNIT 11WL DISPLAYED DURING SYSTEM TEST. MAINTENANCE REPLACED BATTERY FOR EMERGENCY POWER SUPPLY UNIT 11WL AND ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK PER AMM 33-51-38 WITH NO FAULTS NOTESDR AALA202506121502Fitting · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON FORWARD RIGHT PASSENGER / CREW DOOR CUT OUT LOWER SILL CENTER SHAPE FITTING BETWEEN FR 16 AND FR 20 AT S23R. REPLACED CENTER SHAPE FITTING PER SRM 51-42-11.SDR AALA202506125016Battery · no testAIRCRAFT WAS NOT GROUNDED: BATTERY FAULT FOR EMERGENCY POWER SUPPLY UNIT 10WL DISPLAYED DURING SYSTEM TEST. MAINTENANCE REPLACED BATTERY FOR EMERGENCY POWER SUPPLY UNIT 10WL AND ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK PER AMM 33-51-38 WITH NO FAULTS NOTESDR AALA202506127012Fuel Filter · cloggedAIRCRAFT WAS NOT GROUNDED: ENGINE 1 FUEL FILTER CLOG ECAM CAME ON AFTER TAKEOFF AND REMAINED ON FOR 30 MINUTES THEN EXTINGUISHED. MAINTENANCE REPLACED FUEL FILTER AND ACCOMPLISHED A SATISFACTORY LEAK / OPERATIONAL CHECK PER AMM 73-11-10.SDR AALA202506120615Door · stuckAIRCRAFT WAS NOT GROUNDED: AFT LAVATORY-D DOOR WILL NOT LOCK AND GETS STUCK. TOP DOOR FRAME TRIM FOUND INCORRECTLY INSTALLED. CORRECTLY INSTALLED TRIM. PER CMM 25-40-58. DOOR NOW OPERATES AND LOCKS SMOOTHLY.SDR AALA202506125603Battery Pack · inoperativeAIRCRAFT WAS NOT GROUNDED: L2 EMERGENCY EXIT EXTERIOR LIGHT INOPERATIVE. REMOVE AND REPLACE BATTERY PACK 5026. PER AMM 33-51-06.