Service difficulty reports
1,771,708 reports of malfunctions and defects, newest first. Air carriers must report; general aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR AALA202506124491Power Supply · inoperativeAIRCRAFT WAS NOT GROUNDED: R1 INTERIOR EMERGENCY EXIT SIGNS UPPER AND LOWER INOPERATIVE. REMOVED AND REPLACED BATTERY POWER SUPPLY M02816 LOCATED AT FORWARD OVERHEAD GALLEY. PER AMM 33-51-06.SDR AALA202506129917Power Supply · inoperativeAIRCRAFT WAS NOT GROUNDED: FIRST CLASS AISLE EMERGENCY LIGHTS BETWEEN SEATS 1 THROUGH 4 INOPERATIVE. REMOVED AND REPLACED BATTERY POWER SUPPLY M02816 LOCATED AT FORWARD OVERHEAD GALLEY. PER AMM33-51-06.SDR AALA202506128410Power Supply · inoperativeAIRCRAFT WAS NOT GROUNDED: R1 EMERGENCY EXTERIOR LIGHT INOPERATIVE. REMOVED AND REPLACED BATTERY POWER SUPPLY M02816 AT THE FORWARD OVERHEAD GALLEY. PER AMM33-51-06.SDR AALA202506122667Anti-Ice Valve · warning lightAIRCRAFT WAS GROUNDED: AN EMERGENCY WAS NOT DECLARED DUE TO: WHILE IN CRUISE FLIGHT AT FL330 ICING CONDITIONS WERE ENCOUNTERED AND ENGINE ANTI-ICE WAS TURNED ON. THE NUMBER 1 ENGINE BLUE COWL VALVE OPEN LIGHT ILLUMINATED BRIGHT AND DID NOT DIM. SHORTLY THERE ASDR DXTA2025061203870Switch · unknownON ARRIVAL PASSING 10K FEET, THE PAX SAFETY SWITCH WAS SELECTED TO THE ON POSITION AND NONE OF THE APPROPRIATE LIGHTS TURNED ON IN THE CABIN AND WE WERE UNABLE TO SEE THE EXTERIOR WING LIGHT. ON THE GROUND WE TURNED THE EMER LTS SWITCH TO ON AND THE LIGHTS CAMSDR DALA2025061204468Actuator · inoperativeSHIP 3250 AFTER BOARDING F/A CALLED UP SAYING SHE SMELLED A BURNING SMELL IN AFT CABIN. PAX NOTICED IT ALSO PACKS HAVE BEEN BLOWING HOT AIR INTERMITTENTLY WITH PACK FULL COLD. HOT AIR VALVE IS OPEN WHEN THIS HAPPENS. OBSERVED THE FOLLOWING W/ BOTH PACKS ON -SDR DALA2025061204467Bottle · low pressureSHIP 3270 DISC: WHILE PERFORMING PSGR COMPT 1A CHECK, FOUND LIFE RAFT PRES LOW ( O/H BIN 32A). C/A: FWD TO MEL 25-60-16D PLAC & MEL APPLIED NO "M" PROCS MCC CONTACTED FOR DISP APPROVAL. (LP: 7383095)SDR FDEA202506110922Skin · dentedLH WING, INBOARD FLAP, AFT FLAP LOWER SURFACE WITH DENT LH WING, INBOARD FLAP, AFT FLAP LOWER SURFACE WAS REPAIRED IAW B767 SRM 57-53-01-01A AND SRM 51-70-03-06 PAR 5,B FIG. REV 90 AUG 15,2024 PAINT WAS RESTORED IAW B767 AMM 51- 21-10-307-020 REV 145 APR 2SDR QMLA202506120001Pump · faultedF PUMP FWD AND F PUMP AFT CAUTIONS DISPLAYED WITH 24 US GAL OF FUEL INDICATED IN THE MAIN FUEL TANK. NEITHER PUMP OPERATED WITH CHANGE IN AIRCRAFT ATTITUDE AS SPECIFIED IN THE RFM EMERGENCY PROCEDURE, RESULTING IN DRAWING
DOWN FUEL LEVEL IN EACH ENGINE SUPPLYSDR SCNA20250612208Battery Pack · no testEMER BATTERY PACK FOR AFT SERVICE DOOR FAILED TEST - RESOLUTION: R&R EMER BATTERY PACK FOR AFT SERVICE DOOR REF AMM 33-51-06 OPS CHECK GOODSDR MASA2025061000048Megaphone · brokenMEGAPHONE BULLHORN FOUND BROKEN. MESA MAINTENANCE REMOVED AND REPLACED MEGAPHONESDR CALA2025061205527Unknown · odorELECTRICAL BURNING SMELL COMING THROUGH COCKPIT AIR VENTS UNABLE TO DUPLICATE FAULT/SMELL. PERFORMED OPERATIONAL TEST PER AMM 21-25-00. OPERATIONAL CHECK GOOD. PILOTS DO NOT SMELL ANY BURNING ODOR/SMOKE.SDR CALA2025061205526Charger · faultedFOUND SLIDE/OVERWING EMERGENCY LIGHTS INOP AT DOOR 2L & 4L RELAMPED DOOR 2L SLIDE OVER WINGLIGHT, OPS CHECK GOOD. REF AMM 33-51-04-960-801. REPLACED THE FUSE ON CHARGER AT DOOR 4L, OPS CHECK GOOD. REF AMM 33-51-06-960-801.SDR CALA2025061205506Support Fitting · corrodedAFT CARGO LWR DOOR SILL THRESHOLD 2ND SUP PORT FITTING HAS CORROSION AS MARKED AND AROUND THE NUTPLATES. REMOVED AND REPLACED FITTING P/N 69-45578U7 IAW B757-300 SRM 51- 10-02 AND SRM 51-40-02.SDR CALA2025061205505Transition Panel · corrodedAFT CARGO FLOOR R/H TRANSITION PANEL HAS CORROSION FROM STA 1310-1380. CORROSION ON TRASITION PANEL STA 1310-1380 RH SIDE AND FOUND TO BE EXFOLIATED OUT OF LIMITS IAW B757-300 SRM 53-00-53- 1A-1. REMOVED AND REPLACED TRANSITION PANEL STA 1310-1380 RH SID E IASDR CALA2025061205504Battery Pack · failedEMERGENCY LIGHTS BATTERY PACK M1695 FAILS OPERATIONAL CHECK (REF: AAR NR 1000041152) REMOVED PWR SUPPLY BATTERY PACK (M1695) SN: 416389 AND INSTALLED NEW PWR SUPPLY BATTERY PACK (M1695) SN: 383653 IAW B737 AMM 33-51-06-960-805. TEST OK PER B737 AMM 33-51-00-71SDR CALA2025061205503Battery Pack · failedEMERGENCY LIGHTS BATTERY PACK M1694 FAILS OPERATIONAL CHECK (REF: AAR NR 1000041151) REMOVED PWR SUPPLY BATTERY PACK (M1694) SN: 418353 AND INSTALLED NEW PWR SUPPLY BATTERY PACK (M1694) SN: 383733. IAW B737 AMM 33-51-06-960-805. TEST OK PER B737 AMM 33-51-00-7SDR CALA2025061205502Crease Beam · corroded(SDR)(19-5303-1-2082): CABIN FLOOR R/H O/B CREASE BEAM HAS CORRO SION FROM STA 1320-1360, RBL - 64". SFR CW WSHAW REMOVED AND REPLACED CREASE BEAM CHORD P/N 146N832902 BATCH# 000 4400131 AT MAIN CABIN FLOOR STA 1320-1360 IAW B757-300 SRM 51-40 -02-0G-0SDR CALA2025061205501Battery Pack · failedEMERGENCY LIGHTS BATTERY PACK M1672 FAILS OPERATIONAL CHECK (REF: AAR NR 1000041150) REMOVED PWR SUPPLY BATTERY PACK (M1672) SN: 370270 AND INSTALLED NEW PWR SUPPLY BATTERY PACK (M1672) SN: 383650 IAW B737 AMM 33-51-06-960-805. TEST OK PER B737 AMM 33-51-00-71SDR CALA2025061205500Mount Bracket · crackedLEFT MLG W/W HYD FILTER MODULE MOUNTING BRACKET HAS A CRACK AS MARKED, AREA ABOVE THE ELECTRIC HYDRAULIC PUMP. REMOVED AND REPLACED BRACKET ON L/H MLG W/W HYD FILTER MODULE IA W SRM 51-40-02.SDR CALA2025061205499Battery Pack · failedEMERGENCY LIGHTS BATTERY PACK M1671 FAILS OPERATIONAL CHECK (REF: AAR NR 1000041149) REMOVED PWR SUPPLY BATTERY PACK (M1671) SN: 418332 AND INSTALLED NEW PWR SUPPLY BATTERY PACK (M1671) SN: 383647 IAW B737 AMM 33-51-06-960-805. TEST OK PER B737 AMM 33-51-00-71SDR CALA2025061205498Battery Pack · failedEMERGENCY LIGHTS BATTERY PACK M1670 FAILS OPERATIONAL CHECK (REF: AAR NR 1000041148) REMOVED PWR SUPPLY BATTERY PACK (M1670) SN: 418388 AND INSTALLED NEW PWR SUPPLY BATTERY PACK (M1670) SN: 383648. IAW B737 AMM 33-51-06-960-805. TEST OK PER B737 AMM 33-51-00-7SDR CALA2025061205497Seat Track · corrodedMAIN CABIN O/B SEAT TRACK BEAM Y-765 RT) HAS CORROSION SPOTS AT FR20 R/H A3NB-53-3-6038 ESFR CORRECTION FROM LOCATION RH TO LH ESFR ENTERED CORRECTION RH BETWEEN FR12 AND FR24 LBL 20 REMOVED AND REPLACED SEAT TRACK-BEAM Y-765 AT MAINN CABIN R/H BT W FR12-24 IASDR DALA2025061104459Seat Track · corrodedAIRCRAFT 9572, CORROSION WAS FOUND OUT LIMITS ON SEAT TRACKS STA Y=906-1015 X=-56 AT PASSENGER CABIN (CPAX). CORRECTIVE ACTION: CORROSION LEVEL 2, SEAT TRACKS STA Y=906-1015 X=-56 AT PASSENGER CABIN (CPAX) WAS REPAIRED PER B717-200 SRM 53-20-52-2R PROCEDURE 1 SDR IXX202506110012Floorbeam · corrodedCORROSION ON THE UPPER CHORD OF THE CABIN FLOORBEAM, AROUND THE FASTENER HOLE AT STA 1640, LBL54 #79247.SDR F3LA202506110247Battery · failedAIRCRAFT WAS NOT GROUNDED AND IS IN CHECK FOR SCHEDULED MX. DURING INCOMING CHECKS FOUND EPSU BATTERIES 13 WL INOP, REPLACEMENT REQUIRED AS PER AMM 33-51-38-04 CONF 00 REV. 102
CORRECTIVE ACTION: REPLACED EPSU BATTERY 13WL IAW AMM 33-51-38-400-001 CONF 00 RESDR YENA2025061100584Outflow Valve · failedFLT#195, HPN-MCO (AIRCRAFT DIVERTED TO JFK). 'CAB PR EXCESS CAB ALT ECAM AT FL 320 TO 10500 FT. AS WE INITIATED EMG DESCENT CABIN ALT REMAINED OVER 10000 FT AS WE MADE OUR RAPID DESCENT TO 10K; REMOVED AND REPLACED OUTFLOW VALVE IAW AMM 21-31-51. OPS CHECK GOOSDR 2025FA0000400Valve Guide · cokedCREW REPORTED ROUGH RUNNING ENGINE/VIBRATION IN CRUISE FLIGHT LASTING 2-3 MINUTES ALONG WITH A # 2 CYLINDER EGT FLUCTUATION. TROUBLESHOT PROBLEM TO FIND # 2 CYLINDER EXHAUST VALVE STICKING.SDR SWAA2025061180307Battery Pack · failedR/H FWD. EMERGENCY LIGHTING BATTERY PACK FAILED THE CAPACITY CHECK. REMOVED & REPLACED R/H FWD EMERGENCY LIGHTING BATTERY PACK PER AMM 33-51-06.SDR SWAA2025061180488Battery Pack · inoperativeFWD OVERWING EXIT EMERGENCY LIGHT INOP<[01] REMOVED AND REPLACED BATTERY PACK M2335 PER AMM 33-51-06 OPS CHECK GOOD.SDR SWAA2025061180487Battery Pack · inoperativeFWD SERVICE DOOR ESCAPE SLIDE EMERGENCY LIGHT INOP<[01] REMOVED AND REPLACED BATTERY PACK M2816 PER AMM 33-51-06 OPS CHECK GOOD.SDR SWAA2025061180289Scuff Plate · crackedFORWARD CARGO THRESHOLD BULLNOSE IS SPLIT; CRACKED.<[01] 01 - REMOVED AND REPLACED PER [AMM 53-11-02-401-NG (CARGO DOOR SCUFF PLATE - REMOVAL/INSTALLATION - PERMANENT)];[02] VERIFIED REMOVED AND REPLACED PER AMM 53-11-02-401-NG CARGO DOOR SCUFF PLATE .SDR IPXA2025061152431Attach Bracket · debondedF/O'S ESCAPE ROPE DOOR ATTACH BRACKETS DISBONDED FROM PANEL, PANEL IS LOOSE DEFERRED F/OS ESCAPE ROPE DOOR PANEL IAW SREO-84962-REQ001 ACOMPLISHED STEPS TO REMOVE AND STOW PANEL AND INSPECT AREA AND ROPE FOR SECURITY IAW SREO-84962-REQ001SDR IPXA2025061158372Evas Unit · abnormalCAPTAINS EVAS TEST TOOL MISSINGSDR IXXA2025061101Subframe · corrodedCORROSION ON THE CABIN SUBFLOOR AT STA 1716 BLO TO LBL38SDR QR9R2025061100001Sensor · faultyDURING HOVERING FLIGHT, THE GEN AMPS SPLIT MORE THAN 10 AMP. #1 GEN AMPS WAS 10 AND #2 WAS 30. WHEN SHUTTING DOWN THE A/C, THE GEN AMPS RETURNED TO WITHIN 10 AMPS BUT THEN SPLIT AGAIN MORE THAN 10 AMPS. REMOVED AND REPLACED TRANSFORMATOR IAW AMM 24-30-00, 4-6;SDR DALA2025061104445Indicator · inoperativeSHIP 5805 LT AFT DOOR SLIDE ARM LIGHT INOP. CORRECTIVE ACTION: FOUND GIRT BAR END BAR NOT SECURED IN CAM. SECURED END OPS CKS GOOD. (7251896)SDR FDEA202506110921Repair · corrodedDOT 80-065 AFT CARGO COMPARTMENT CEILING STRUCTURE. FLOOR BEAM LOWER FLANGE. F/S 1560 APPROX 10 INCHES FROM R/H SIDEWALL BEAM CORRODED REMOVED DAMAGES AT AFT CARGO LWR FLANGE F/S IAW SRM 51-10-02, FOUND TO BE OUT OF LIMITS IAW SRM 53-60-51-1A. REPAIRED FLOSDR FDEA202506110920Floorboard · wornMAIN DECK CARGO COMPARTMENT, FLOOR PANEL 251AFF DENTED, APPROXIMATELY STATION 1124. GM60 REPAIRED FLOOR PANEL 251AFF (MPN 146T5869-8) AT STA 1100 TO STA 1197 22, LBL11 TO RBL11 IN REF TO B767 SRM 53-00-50-2R FIG 201, REPAIR 1 SHEET 4. THIS IS A MAJOR REPAISDR FDEA202506110919Floor Panel · wornMAIN DECK CARGO COMPARTMENT, FLOOR PANEL 231AFF DENTED, APPROXIMATELY STATION 424. GM46 FABRICATED NEW FLOORPANEL 231AFF MPN:143T5875-5 RBL 11 - LBL 11, STATION 412- 434 IN REF TO BOEING DWG 143T5875-5. THIS IS A MAJOR REPAIR. REMOVED FLOOR PANEL 231 AFF SDR FDEA202506110918Floorboard · dentedMAIN DECK CARGO COMPARTMENT, FLOOR PANEL 222AFF HAS NUMEROUS DENTS, APPROXIMATELY STATION 350. GM39 FABRICATED FLOOR PANEL 222AFF MPN 141T5856-107 RBL 11- RBL 33 STATION 285- STATION 412 IN REF TO BOEING DRAWING 141T5856-107. THIS IS A MAJOR REPAIR. SEE JPSDR FDEA202506110917Floor Panel · dentedMAIN DECK CARGO COMPARTMENT, FLOOR PANEL 222BFF HAS NUMEROUS DENTS, APPROXIMATELY STATION 350. GM40 FABRICATED NEW FLOORPANEL 222BFF MPN: 141T5856-106 RBL 33- RBL 54.75 STA 285-412 IN REF TO BOEING DWG 141T5856-106. THIS IS A MAJOR REPAIR. SEE JPF FOR ALL SDR FDEA202506110916Stringer · crackedDURING ACCOMPLISHING W/C : 57.11.01.1, FOUND CRACK ON UPPER AUXILLIARY TANK LOWER STRINGER S-47, ALONG XCW -17. (RIGHT HAND SIDE). CRACKED STRINGER S-47 ALONG XCW -17 AT UPPER AUXILLIARY TANK LOWER AREA REPAIRED AS PER MD-11 SRM 57-10-03-2R FIGURE 201 REPASDR FDEA202506110915Stringer · crackedDURING ACCOMPLISHING W/C : 57.11.01.1, FOUND CRACK ON UPPER AUXILLIARY TANK LOWER STRINGER S-47, ALONG XCW 17. CRACKED STRINGER S-47 ALONG XCW 17 AT UPPER AUXILLIARY TANK LOWER AREA REPAIRED AS PER MD-11 SRM 57-10-03-2R FIGURE 201 REPAIR 1. REPAIR CLASSIFIESDR FDEA202506110914Stringer · crackedDURING ACCOMPLISHING W/C : 57.11.01.1, FOUND CRACK AT UPPER AUXILLIARY TANK LOWER STRINGER S-47, ALONG XCW -46.5. (RIGHT HAND SIDE). CRACKED STRINGER S-47 ALONG XCW -46.5 AT UPPER AUXILLIARY TANK LOWER AREA REPAIRED AS PER MD-11 SRM 57-10-03-2R FIGURE 201 SDR FDEA202506110913Stringer · crackedDURING ACCOMPLISHING W/C : 57.11.01.1, FOUND CRACK ON UPPER AUXILLIARY TANK LOWER STRINGER S-47, ALONG XCW 46.5. CRACKED STRINGER S-47 ALONG XCW 46.5 AT UPPER AUXILLIARY TANK LOWER AREA REPAIRED AS PER MD-11 SRM 57-10-03-2R FIGURE 201 REPAIR 1. REPAIR CLASDR FDEA202506110912Stringer · crackedDURING ACCOMPLISHING W/C : 57.11.01.1, FOUND CRACK ON UPPER AUXILLIARY TANK LOWER STRINGER S-46, ALONG STATION XCW -46.5. (RIGHT HAND SIDE). REPAIR CARRIED OUT AT UPPER AUXILLIARY TANK LOWER STRINGER S-46, ALONG STATION XCW -46.5 (RIGHT HAND SIDE) AS PER SDR FDEA202506110911Longeron Splice · corrodedLOWER FORWARD CARGO COMPARTMENT BILGE AREA LONGERON SPLICE FITTING FOUND CRACK AT STATION 6-0 LONGERON 50 RIGHT. LOWER FORWARD CARGO COMPARTMENT BILGE AREA CRACKED LONGERON SPLICE FITTING AT STATION 6-0, LONGERON 50 RIGHT REMOVED AND REPLACED WITH FABRICATSDR FDEA202506110910Longeron · corrodedLOWER FORWARD CARGO COMPARTMENT BILGE AREA LONGERON FOUND WITH CORROSION BETWEEN STATION 1038-1059 LONGERON 52. LOWER FORWARD CARGO COMPARTMENT BILGE AREA LONGERON 52 BETWEEN STATION 1038- 1059 CORROSION REMOVED AND FOUND OUT LIMIT PER MD-11 SRM 53-00-00-2RSDR FDEA202506110909Seat Track · wornCABIN SEAT TRACK AT STATION 1545 X = -47.5 FOUND CROWN WORN. CABIN-AT SEAT TRACK STATION 1545, X= -47.5 WORN CROWN EVALUATED AND FOUND EXCEEDED LIMIT AS PER MD-11 SRM 53-00-52-1A FIGURE 101 ALLOWABLE DAMAGE 1. CROWN WORN SEAT TRACK REPAIRED BY SECTIONAL S