Service difficulty reports
1,771,708 reports of malfunctions and defects, newest first. Air carriers must report; general aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR REXA2025061800669Intercostal · corrodedPAX DOOR DD2 FWD FOUND TO BE CORRODED. REQUIRES REPLACEMENT INSTALLED FWD DD2 INTERCOSTAL IAW CRJ900 SRM 51-42-06-001-001-A01SDR SWAA2025061776882Handle · deterioratedDETERIORATED ENTRY DOORWAY LINNING NUT ASSIST HANDLE AT FWD GALLEY AREA. REPLACED ENTRY DOORWAY LINNING NUT ASSIST HANDLE AT FWD GALLEY AREA (2 EA) IAW B737-700 AMM 25-21-31-420-802 STEP 3.B.(6).SDR SWAA2025061776883Handle · deterioratedDETERIORATED LINING ENTRY DOOR NUT UPPER ASSIST HANDLE AT FWD GALLEY AREA. REPLACED LINING ENTRY DOOR NUT UPPER ASSIST HANDLE AT FWD GALLEY AREA (2 EA) IAW B737-700 AMM 52-11-31-400-802 STEP 3.G.(2).SDR SWAA2025061776884Handle · deterioratedDETERIORATED ENTRY DOORWAY LINNING NUT ASSIST HANDLE AT AFT GALLEY AREA. REPLACED ENTRY DOORWAY LINNING NUT ASSIST HANDLE AT AFT GALLEY AREA IAW B737-700 AMM 25-21-25-420-801 STEP 3. B. (5).SDR SWAA2025061776878Scuff Plate · crackedCRACK ON FWD CORNER SCUFF PLATE AT FWD CC. REPAIRED FWD CORNER SCUFF PLATE AT FWD CC IAW BOEING 737-700 SRM 53-30-15-2R-1 REPAIR 1 AND BAC 5975.SDR SWAA2025061776879Scuff Plate · crackedCRACK ON SCUFF PLATE AT FWD SERVICE DOOR. REPAIRED SCUFF PLATE AT FWD SERVICE DOOR IAW B737-700 SRM 53-10-15-2R-2 REPAIR 2.SDR SWAA2025061780357Scuff Plate · crackedCRACK ON CENTER SCUFF PLATE LOCATED ON FWD CC REPAIRED CENTER SCUFF PLATE LOCATED ON FWD CC COMPARTMENT IAW BOEING 737-700 SRM 53-30-15-2R-1 REPAIR 1 AND BAC 5975.SDR SWAA2025061276872Floor Panel · delaminatedPASSENGER CABIN FLOOR PANEL 242CF IS DELAMINATED. DUE TO EXTENT OF THE DAMAGE FABRICATED NEW 242CF FLOOR PANEL IAW SRM 53-00-50-2R-0.SDR SWAA2025061276870Floor Panel · delaminatedPASSENGER CABIN FLOOR PANEL 241DF IS DELAMINATED. DUE TO EXTENT OF THE DAMAGE FABRICATED NEW 241DF FLOOR PANEL IAW SRM 53-00-50-2R-0.SDR SWAA2025061276873Floor Panel · delaminatedPASSENGER CABIN FLOOR PANEL 241BF IS DELAMINATED AND DAMAGED PLACARD, DUE TO EXTENT OF THE DAMAGE FABRICATED NEW 241BF FLOOR PANEL IAW SRM 53-00-50-2R-0.SDR SWAA2025061276874Floor Panel · delaminatedPASSENGER CABIN FLOOR PANEL 241AF IS DELAMINATED. PASSENGER CABIN FLOOR PANEL 241AF WITH DELAMINATED WAS REPLACED WITH A NEWLY FABRICATED FLOOR PANEL DUE TO AMOUNT OF ALL DAMAGE IAW SRM 53-00-50-2R-0, & DWG 144A5810 ID:0127.SDR SWAA2025061276871Floor Panel · delaminatedPASSENGER CABIN FLOOR PANEL 231XF IS DELAMINATED. PASSENGER CABIN FLOOR PANEL 231XF WITH DELAMINATED WAS REPLACED WITH A NEWLY FABRICATED FLOOR PANEL DUE TO AMOUNT OF ALL DAMAGE IAW SRM 53-00-50-2R-0, AND; DWG 144A5810 ID:0126.SDR SIMA20250531002Doubler · corrodedSSI 53-10-027 FWD GALLEY LH FLOOR DOUBLER HAS CORROSION AT FR 19. (LEVEL 2 CORROSION). REMOVED AND REPLACED FWD GALLEY LH FLOOR DOUBLER AT FR 19 IAW ERJ 175 SRM 51-40-08.SDR SIMA20250531003Floorbeam · corrodedSSI 53-10-027 FWD GALLEY RH FLOOR BEAM HAS CORROSION AT FR 17. (MAJOR REPAIR) (LEVEL 2 CORROSION) PERFORMED CUT-OUT ON DAMAGED PORTION OF THE BEAM UPPER CAP ON THE FWD GALLEY RH FLOOR BEAM AT FR 17 IAW ERJ 175 SRM 53-10-10 RE01. FABRICATED AND INSTALLED REPAIRSDR SWAA2025061076837Battery Pack · inoperativeEMERGENCY EXIT LIGHTS ASSOCIATED WITH BATTERY PACK (M1672) DO NOT ILLUMINATE. REMOVED AND REPLACED BATTERY PACK M1672 IAW AMM 33-51-06-960-805 AND PERFORMED GOOD EMERGENCY LIGHT TEST IAW AMM 33-51-06-960-805.SDR IPXA2025060974047Strap · corrodedCORROSION-U CHANNEL, FORWARD CARGO COMPARTMENT AROUND CEILING PANEL NUTPLATES AREA BETWEEN STA 566 AND STA 610, RBL 40.(REPLACE) 1. JOB COMPLETED.SDR IPXA2025060773271Battery · inoperativeFOUND THE UPPER DECK AISLE EMERGENCY LIGHT INOP. (REPLACE). .I.A.W AMM 33-51-04-900-803 REV.47 REPLACED THE EMERGENCY LIGHT BATTERY (M5169) AND PERFORMED UPPER DECK EMERGENCY LIGHT TEST, RESULT WAS SATISFACTORY. REVIEWED TASK PER GMM-MTX 09.05.01.09.SDR IPXA2025060773258Battery · inoperative**SUPPLEMENTAL SDR** FAULT-FOUND THE L1 DOOR EMERGENCY LIGHT INOP.(REPLACE). I.A.W AMM 33-51-04-900-803 REV.47 REPLACED THE EMERGENCY LIGHT BATTERY (M5170) AND PERFORMED THE L1 DOOR EMERGENCY LIGHT TEST, RESULT WAS SATISFACTORY. REVIEWED TASK PER GMM-MTX 09.0SDR AALA202506109266Pressure Switch · inoperativeAIRCRAFT WAS NOT GROUNDED: UPON LANDING WITH AUTOBRAKE 3, BRAKES DID NOT ACTIVATE AND THE DISARM LIGHT ILLUMINATED, SPOILERS WERE SLOW TO DEPLOY, AND POWER WANTED TO COME BACK UP TO FLIGHT IDLE. PER FIM 32-42-00-810-807, REMOVE AND REPLACED SERVO VALVE PRESSURSDR SIMA202506101001Seat Track · corrodedSSI 53-10-027 ? FWD GALLEY LH FLOOR BEAM HAS CORROSION AT FR 19- FR 20. (MAJOR REPAIR) (LEVEL 2 CORROSION) RAR LH FLOOR BEAM BTW FR 12 ? FR 20 IAW ERJ 175 SRM 51-40-08.SDR IPXA2025060971981Skin · corrodedRIGHT WING INBOARD MAIN FLAP TE LOWER SKIN INSIDE SUSPECT CORROSION, IFS 105.75. ACCOMPLETED REPAIR IAW EO-94005-REQ1 REV1.SDR IPXA2025060681128Floor Panel · delaminatedAFT CARGO FLOOR PANEL 152 SF IS DELAMINATED. FABRICATED NEW FLOOR PANEL IAW SREO-16407-REQ002SDR REXA2025060900653Floorbeam · corrodedRH FS280 CROSSBEAM IS CORRODED BETWEEN BL 0 AND RBL 9. REMOVED CORROSION FROM UPPER FLANGE OF RH FS280 CROSSBEAM P/N CC670-34094-2 FROM BL 0 TO RBL 9 PER CRJ 900 SRM 51-21-06-001-001-A01. BLEND IS NOT WITHIN THE ALLOWABLE DAMAGE LIMITS SPECIFIED BY CRJ 900 SRSDR DALA2025060604345Transformer · failedSHIP 9557 STRONG ELECTRICAL ODOR ON FINAL RIGHT S THE GEAR WENT DOWN AND FLAPS WENT TO 18 DEGREES. R/R TRANSFORMERS TI-5 AND T1-6.(T1-5 SMELLED BURNT) PER B717 SWPM 20-20-03. RT NOSE LDG AND TAXI LIGHT CKS OK. C/B FUNCTION NORMAL. REF B717 WDM 34-41-01 (72629SDR DALA2025060604341Access Panel · corrodedSHIP 9577 IN REFERENCE NRC S/N:00617: CORROSION OUT OF LIMITS ON FUEL ACCESS PLATE COUNTERSINK 620DT PER B717-200 SRM 57-10-01-2R PROCEDURE 2. DOOR CAN NOT BE REPAIRED UNDER CONDITION I OR II. CORRECTIVE ACTION: REPAIRED PER B717 AMM 57-11-02- 300-801 (0998316SDR DALA2025060604340Skin · dentedSHIP 9577 INITIAL INSPECTION: DENT ON EXTERNAL FUSELAGE SKIN ON STA Y=213 BTW LONG= 18L AND LONG=19L AT LOWER FUSELAGE. CORRECTIVE ACTION: REPAIRED PER ER/A 625868-14 REV ORIGINAL (0996949)SDR CALA2025060605340Unknown · vibrationMULTIPLE THUMPS/VIBRATIONS DURING CLIMB BTWN 7K-15K ALT AT 250-2 80 KTS. LOCKED FOR FERRY T/S IN PROGRESS.SDR DALA2025060504286Connector · damagedWHILE WORKING ODI LOG #7412850, FOUND FWD GALLEY COFFEE MAKER PIN AND CONNECTOR A4070P1 SOCKET 5 BURNED FROM ARCING. SOCKET 5 AT CONNECTOR A4070P1 IS BURNT AND ELEC CONNECTOR AT POSITION 102 IS DAMAGED DUE TO ARCING. (571824). C/W SECTION 1: TIME LIMITED ALTERSDR AALA202506045074Computer · leakingAIRCRAFT WAS GROUNDED: MODERATE MUSTY AND DIRTY SOCK ODOR JUST AFTER SETTING TAKEOFF THRUST, IT CONTINUED THROUGH CLIMB TO APPROXIMATELY 10,000 FT. SUSPECT OIL SEAL SEEPAGE. DURING FAULT ISOLATION FOR SOF EVENT, FOUND ELEVATOR FEEL COMPUTER LEAKING, WITH LEAKSDR AALA202506043726Engine · flamed outAIRCRAFT WAS GROUNDED: AN EMERGENCY WAS DECLARED DUE TO: HEARD LOUD POP NOISE ON TAKEOFF ROLL, ENGINE COMPRESSOR STALL DURING TAKEOFF. AIRCRAFT REJECTED TAKEOFF AT 110 KNOTS AND RETURN TO BLOCK SAFELY AT STL. C/W FIM 71-05-00-810-805-F00. FOUND FAN LOCKED UP ASDR YENA2025060400561Unknown · odorFLT#598, MCO-LGA.' DURING DESCENT BELOW 10000' INTERMITTENT CHEMICAL SMELL OF LOW TO MEDIUM INTENSITY APU WAS OFF; COMPLISHED WITH INFORMATION NOTICE 2017-T015 SECTION A ISOLATED FAULT TO TYPE 10 SUSPECT AMBIENT AIR AT LOCAL AIRPORT (LGA) HIGH PRECIPITATION / SDR CALA2025060405271Unknown · vibrationMODERATE LATERAL VIBRATION. STARTED AT 17000-F230. SPEED WAS APP ROX 300 KTS CI 40..SLOWED TO FOUND YELLOW AN GREEN HYD QTY LOW, SERVICED BOTH SYS TO FULL IAW AMM 12-12-29-611-001-A, PREFORMED VISUAL INSP OF ACFT FOR HYD LEAKS NONE FOUND, VERIFIED NO OSCILLATISDR CALA2025060405270Engine · making metalCREW REPORTS - #1 ENG FAILED CREW REPORTS- #1 ENG FAILED 400FT AGL 10 SEC AFTER ROTATION, EGT SPIKED (RED LINED) TO 785, SHOWED 605 AFTER ENGINE SHUTDOWN. A/ C YAWED TO THE LEFT, CREW LEVELED A/C AT 1500 FT. SAW ENGINE HAD FAILED AND FA SAID THEY HEARD A LOUD SDR CALA2025060405269Control Unit · faultedMULT FA COMPLAINED OF BEING LIGHT HEADE AND NAUSIA AFTER T/O WIT H EXHAUST SMELL IN BACK REF AMM05-51-56. ACCOMPLISHED AMM 05-51-56 INCLUDING HIGHPOWER RUNS WITH LEFT AND RIGHT PACKS ISOLATED. ALSO RAN PACKS WITH APU NO SMELL IN CABIN NOTED. SEE LOG PAGE 50529SDR CALA2025060405263Fuel Cap · missingPDA 2 FUEL CAP FOUND MISSING ON WALK AROUND IN ORD VUSUALLY INSPECTED VACINITY OF REFUEL POINT, NO DAMAGED NOTED. CONTACTED IAH HMC, FUEL CAP HAS YET TO BE LOCATED.SDR NACA2025053100001Radio · weakLEFT HF RADIO ON FULL VOLUME IS WEAK AND UNREADABLE. CAN HEAR THE RADIO IS WORKING BUT NOT LOUD ENOUGH TO UNDERSTAND. PERFORMED OPS CHECK ON LH HF RADIO PER AMM 23-11-00 SPEAKER AND HEADPHONE VOLUME GOOD.SDR ASAA2025053158388Lens · detachedEXIT SIGN COVER FELL OFF ROW 17F. GROUNDED - YES. REPLACED EXIT SIGN LENS REF AMM 33-51-01.OPS CHECK OK.SDR ASAA2025053158386Power Supply · inoperativeEMERGENCY EXIT LIGHT BY L1 DOOR DAMAGED AND INOP. GROUNDED - YES. REMOVED AND REPLACED EMERGENCY LIGHTS POWER SUPPLY ASSY M1670 AND M1675 REF BOEING AMM TASK 33-51-06-960-806. OP TEST GOOD WITH EMERGENCY LIGHTS ILLUMINATING AS REQUIRED. NO FURTHER DEFECTS.SDR ABXA20250531115Blowout Panel · missingDURING INSPECTION AT MIA, MAINTENANCE FOUND ON RIGHT ENGINE ON O/B SIDE OF RADIANT HEAT SHIELD BLOW OUT PANEL MISSING. INSTALLED NEW BLOW OUT PANEL "RADIANT HEAT SHIELD" ON O/B SIDE OF RIGHT ENG IAW AMM 72-31-00. A/C REMAINS NO ETOPS. DEFERRED MISSING LANYASDR ABXA20250531114Blowout Panel · missingDURING INSPECTION AT MIA, MAINTENANCE FOUND ON LEFT ENGINE ON I/B SIDE OF RADIANT HEAT SHIELD BLOW OUT PANEL MISSING. INSTALLED NEW BLOW OUT "RADIANT HEAT SHIELD" ON I/B SIDE OF LEFT ENG IAW AMM 72-31-00. A/C REMAINS NO ETOPS. DEFERRED MISSING LANYARD PER ASDR DALA2025060304249Bustle · looseSHIP 6806 COMPONENTS HANGING FROM UNDER SLIDE BUSTLE WHEN DOOR OPEN. CORRECTIVE ACTION: REMOVED BUSTLE AND SECURED LOOSE MATERIAL. REINSTALLED BUSTLE. RII C/W. (0998462)SDR SWAA2025060377046Seat Back · out of adjustSEAT 12F WILL NOT STAY UP. SECURED UPRIGHT. <[01] SECURED SEAT UPRIGHT. REFER LP# 2258629 FOR NEW MEL.; [02] SIGNED OFF AS FACT IN MAINTENIX IN ERROR. CREATED NEW FAULT ON LP# 2258630.SDR SWAA2025060377017Flashlight · failedLH AFT FLASHLIGHT DOES NOT TEST PROPERLY <[01]. REMOVED AND REPLACED L/H AFT FLASHLIGHT PER AMM 25-64-00.SDR SWAA2025060377051Slide · out of adjustAFT CA SIDE SLIDE CAME OUT OF CASE WHILE CLOSING DOOR REF TTG8Q012SC18 FOR M/T SIGNOFF <[01]. REINSTALLED SLIDE AMM 25-66-01.SDR SWAA2025060377061Sign · inoperativeAFT FL.ATT. CALL LT INOP <[01]. OKAY TO CONT. PER M.E.L> 23-19-03 SP#1B. AUTH. # 256009; [02] REMOVED AND REPLACED AFT EMER EXIT SIGN LIGHT ASSY PER AMM 33-51-01.SDR SWAA2025060376710Lamp · inoperativeFWD ENTRY EXTERIOR LIGHT IS INOP <[01]. REMOVED AND REPLACED LAMP ON L1 DOOR EMERGENCY LAMP (EXTERIOR) PER AMM 33-51-04.SDR SWAA2025060376725Lamp · inoperativeL/H OVER WING EMERGENCY LIGHT INOP <[01]. 01 - REMOVED AND REPLACED PER [AMM 33-51-04-960-801-NG (SLIDE/OVERWING LIGHT - LAMP REPLACEMENT - PERMANENT)].SDR SWAA2025060376987Battery Pack · inoperativeR2 DOOR EMERGENCY LIGHTS INOP (HEADER; EXTERNAL; AND LOWER) <[01]. REMOVED AND REPLACED 1 EA EMERGENCY BATTERY PACK M1672 AND OPS CHECK GOOD IAW SWA B737-800 AMM 33-51-06-960-805.; [02] REMOVED AND REPLACED 1 EA EMERGENCY BATTERY PACK M1672 AND OPS CHECK GOODSDR SWAA2025060377039Lens · out of adjustLENS COVER MISSING FOR O/H EMERLIGHT AT ROW 17 <[01]. OK TO CONTINUE PER MEL25-10-02 SP1B; [02] REPLACED LENS COVER FOR ROW 17 PER AMM 33-51-03.SDR SWAA2025060376765Door · crackedTWO CRACKS LOCATED BY APU DOOR FWD HINGE APPROX. 0.17 IN LENGH <[01]. COMPLIED WITH EA 25-153-1441; [02] COMPLIED WITH INSPECTION STEPS OF EA 25-153-1441.