Service difficulty reports
1,773,593 reports of malfunctions and defects, newest first. Air carriers must report; general aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DXTA2025051903517Battery Pack · defectiveEMERGENCY LIGHTING: THE PAST FEW MORNINGS THE EMER LIGHTS DID NOT TEST WITH ARM OR COME ON IN THE ON POSITION DURING PREFLIGHT CHECKS. AFTER CHARGING FOR 15 MINUTES WITH THE APU ON THEY WORKED NORMALLY. CORRECTIVE ACTION; REPLACED ALL EMERGENCY BATTERY PACKS SDR DXTA2025051903525Light · unknownCABIN EMERG LIGHT: CABIN EMERGENCY LIGHTS DO NOT ILLUMINATE WITH AIRCRAFT BATTERIES OFF AND EMERGENCY LIGHT SWITCH IN ARM. EMER LIGHTS DO ILLUMINATE WITH THE EMER SWITCH IN THE ON POSITION. CORRECTIVE ACTION; PERFORMED EMERGENCY LIGHTING ADJUSTMENT/TEST IAW ASDR DXTA2025051903526Control Panel · defectiveMAIN DOOR MOTOR SWITCH: INTERIOR AIRSTAIR DOOR SWITCH INOP. WHEN PRESSED, DOOR WILL NOT CLOSE. CORRECTIVE ACTION; REPLACED INTERIOR MED SWITCH PANEL IAW GLOBAL 5000 MM 52-11-09. OPS CHECK GOOD.SDR DXTA2025051903527Sealant · damagedFUSELAGE PLATES / SKINS / PANELS: DESCENDING THROUGH FL390 NOTICED A LOUD HUM COMING FROM THE CABIN. SEEMED TO BE COMING FROM THE LEFT AFT PART OF THE AIRCRAFT; WAS LOUDEST BY THE REAR MOST WINDOW ON THAT SIDE AND ACCOMPANIED BY A HIGH FREQUENCY VIBRATION. WE SDR AALA202505193680Bottle · low pressureAIRCRAFT WAS NOT GROUNDED: L2 DOOR DAMPER AND EMERGENCY OPERATION CYLINDER PRESSURE LOW. SERVICED DOOR DAMPER AND EMERGENCY OPERATION CYLINDER PER AMM 12-14-29.SDR AALA202505194871Bottle · low pressureAIRCRAFT WAS NOT GROUNDED: R4 DOOR DAMPER AND EMERGENCY OPERATION CYLINDER PRESSURE LOW. SERVICED DOOR DAMPER AND EMERGENCY OPERATION CYLINDER PER AMM 12-14-29.SDR AALA202505195653Mechanism · stickingAIRCRAFT WAS NOT GROUNDED: WHEN OPEING THE 4L DOOR IS STIFF / STICKY. MAINTENANCE CLEANED AND LUBRICATED THE DOOR MECHANISM PER AMM 53-13-11. A SATISFACTORY OPERATIONAL CHECK WAS ACCOMPLISHED.SDR AALA202505193275Plate · looseAIRCRAFT WAS NOT GROUNDED: FLIGHT ATTENDANT REPORTS 2R YELLOW DOOR ARMED PLACARD LOOSE AND INTERFERING WITH ARMING LEVER. MAINTENANCE RESECURED ARM DISARM PADDLE PLATE AND ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK.SDR AALA202505194314Lock · stickingAIRCRAFT WAS NOT GROUNDED: AFT RIGHT LAVATORY E SLIDER LOCK IS STICKING BADLY/NOT WORKING AND TRAPPING PASSENGERS INSIDE LAVATORY. MAINTENANCE LUBRICATED THE LAVATORY DOOR LOCK AND ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK PER AMM 25-45-21.SDR SIMA20250516001Spoiler Sys · faultedSPOILER FAULT EICAS MESSAGE IN FLIGHT. FLT CTRL NO DISPATCH AFTER LANDING. EMERGENCY DECLARED. C/W FLIGHT CONTROL RETURN TOO SERVICE IAW E 175 AMM 27-00-00 OPS CK GOODSDR CALA2025051904829Cap · missingPDA 2 FUEL CAP MISSING AS FOUND ON SERVICE CHECK WALKAROUND. NOTIFIED TOMC NEWMAN REF AMM TASK 28-25-41. REPLACED MISSING FUEL CAP AND LANYARD. NO LEAKS OR DAMAGE NOTED. PARTS USED: 31-2825-9-0001,QTY :1 ROTABLE PARTS CHG SN OFF 4040 PN OFF 31-2825-9-0001 IPSDR CALA2025051904787Skin · dentedDURING REPEAT INSPECTION OF DENT 13" FROM AFT EDGE AT LOWER EDGE FURTHER DAMAGE WAS FOUND. REF HAECO N/R JUL3799 FWD CARGO DOOR AREA 2 DENTS REPAIRED AS PER ECRA 5234-01118. SEE HAECO N/R JUL3799 FOR DETAILS OF WORK ACCOMPLISHED. NOTE: THIS LOGPAGE AND ECRA 52SDR CALA2025051904786Battery Pack · inoperativeEMER EXIT LIGHT COVER BY 1L CAME OFF RESECURED COVER, WHILE OPS CHECK PERFORMED BOTH L1 & R1 DOOR EMERGENCY LIGHT INOP REF AMM TASK 33-51-00-715-019-001. R&R POWER SUPPLY FOR BATTERY PACK M1208 REF AMM 33-51-07, OPS CHECKED GOOD.SDR CALA2025051904785Web · corrodedAFT WET AREA FLOOR STRUCTURE BEAM AT STA 947.5 LBL 4 WITH CORROSION AT UPPER SURFACE AROUND FASTENER HOLE. ACCOMPLISHED REPAIR ON STA 947.5 LBL 4 AS PER ESR-WI 24-12086 P1 REMOVED AND REPLACED WEB AT STA 986.5 TO 1016 LBL32" IAW B737 SRM 51-40-02, AND DRW SDR CALA2025051904784Sign · brokenFA REPORTS EMERGENCY EXIT SIGNED IN MIDDLE ISLE AT DOOR 2 HANGING MID AISLE OVERHEAD EXIT SIGN. SIGN HAS BEEN REMOVED FROM CIELING PANEL A/C SIDE CONNECTOR JUST LAYING IN PLACE. SIGN BROKEN, REQUIRES RR REPLACED THE DR 2L EXIT SIGN ASSY AND OPS CHECK GOOD ATSDR CALA2025051904783Angle · corrodedREMOVED AND REPLACED ZEE ANGLE AT AFT WET AREA AT INTERCOASTAL AREA STA 987 TO 1006 IAW SRM 51-40-02-0G-0 FOR REF AAR N/R 9966931 UPDATE LP TO REFLECT ESFR REMOVED AND REPLACED ZEE ANGLE AT AFT WET AREA AT INTERCOASTAL AREA STA 987 TO 1006 IAW SRM 51-40-02-0G-SDR CALA2025051904782Frame · gougedMAIN CABIN R/H LOWER SIDEWALL FRAME LOWER FWD EDGE SMALL GOUGE STA 663.75 S-16R MKD DOT 137 (REF AAR N/R 9967377) ESFR INFORMATION ADDED ESFR COMPLETE WORK ACCOMPLISHED BY U422520SDR CALA2025051904781Battery Pack · dischargedL2 DOOR FWD EMERGENCY EXIT SIGN DIM. PERFORMED BY EMP V905488,PERFORMED WIRING CHECK AND FOUND M33096 BATTERY MALFUNCTION,REPLACED M33096 BATTERY AND INSTALLATION TE ST PASS,AS PER SSM 33-51-13 REV 91,AMM 33-51-06-960-802 REV 104.SDR CALA2025051904780Battery Pack · dischargedR4 DOOR AFT EMERGENCY LIGHT DIM. PERFORMED WIRING CHECK AND FOUND M33409 BATTERY MALFUNCTION REPLACED M33409 BATTERY AND INSTALLATION TE ST PASS,AS PER SSM 33-51-15 REV 91,AMM 33-51-06-960-802 REV 104.SDR CALA2025051904779Battery Pack · inoperativeL3 DOOR AFTER EMERGENCY EXIT SIGN DIM. PERFORMED WIRING CHECK AND FOUND M33405 BATTERY MALFUNCTION REPLACED M33405 BATTERY AND INSTALLATION TE ST PASS,AS PER SSM 33-51-14 REV 91,AMM 33-51-06-960-802 REV 104.SDR CALA2025051904778Battery Pack · dischargedR4 DOOR FWD EMERGENCY EXIT SIGN DIM. PERFORMED WIRING CHECK AND FOUND M33408 BATTERY MALFUNCTION,REPLACED M33408 BATTERY AND INSTALLATION TE ST PASS,AS PER SSM 33-51-15 REV 91,AMM 33-51-06-960-802 REV 104.SDR CALA2025051904777Battery Pack · inoperativeR3 DOOR FWD EMERGENCY EXIT SIGN DIM. PERFORMED WIRING CHECK AND FOUND M33404 BATTERY MALFUNCTION,REPLACED M33404 BATTERY AND INSTALLATION TE ST PASS,AS PER SSM 33-51-14 REV 91,AMM 33-51-06-960-802 REV 104.SDR CALA2025051904776Battery · dischargedM/D R4 DOOR AFT EMERGENCY POWER SUPPLY M33409 BATTERY PACK FOUND LOW CAPACITY. REPLACED THE M/D R4 DOOR AFT EMERGENCY POWER SUPPLY M33409 BATTERY PACK AS PER AMM 33-51-06-960-802 REV 103, PERFORMED THE NEW BATTERY PACK INSTALLATION TEST AS PER AMM 33-51-06-SDR CALA2025051904763Wire · detachedEMERGENCY EXIT LIGHTS INOP AT SEAT ROWS 33, 34, 35, 36, 37, 38, 39 FOUND TWO SPLICES WITH ONLY ONE END CONNECTED TO EMERGENCY LIGHT AT SEAT 34ABC. JUMPERED WIRES FROM POWER SUPPLY M2626 TO SPLICES AND EMERGENCY LIGHTS AT ROWS 34-39 TURN ON. RETURNED WIRES TO OSDR CALA2025051904762Light · damagedEMERGENCY FLOOR PROX LIGHT INOP AT SEAT 25C FOUND EMERGENCY FLOOR PROX LIGHT ASSY CRACKED AND WIRE PULLED FROM A/C SIDE CONNECTOR. REMOVED AND REPLACED PROX LIGHT ASSY. REF. AMM 33-51-19. PULLED WIRE STILL NEEDS TO BE CRIMPED INTO CONNECTOR. WIRE CRIMP TOOL FOSDR CALA2025051904759Unknown · leakingFOUL SEWAGE SMELL WATER POOLING NEAR L1 DOOR INSPECTED UNDER FWD LAV TOILET SHROUD AND SINK FOR LEAKAGE NONE FOUND. CLEARED FOUL WATER FROM FWD SILL DRAINS REF AMM 38-31-00.SDR CALA2025051904758Unknown · odorPOSSIBLE FUME EVENT ODD SMELL ON FLIGHT DECK DURING TAKEOFF LAST ING UP TO 18000 FT CONTACT TOMC WITH FINDINGS SMOKE AND ORDER REPORT. AT IDLE RUN MUSTY SMELL LEFT ENGINE BLEED ON RIGHT BLEED OFF BOTH PACKS RUNNING UNLOCKING FOR UPDATE ACP SMOKE ODOR CONDITIONSDR DALA2025051903803Oil System · leakingSHIP 5024 UPON DESCENT JFK FA'S REPORTED DIRTY SOCK BURNT RUBBER SMELL IN CABIN. NO PERCEPTABLE SMELL IN COCKPIT, APU OFF. CORRECTIVE ACTION: FOUND OIL PUDDLE BEHIND SPINNER OF #2 ENGINE. R/R FAN SHAFT COVER SEAL PER A321 AMM 72-15 (6862980)SDR DALA2025051703801Light · inoperativeAIRCRAFT 3407, EXIT LIGHT DOOR 3L INOP. CORRECTIVE ACTION: REPLACED EXIT LIGHT AT DOOR 3L AND BATTERY 15WL. CORRECT WIRING AT LIGHT ASSEMBLY. (LP 7126200)SDR 6TXA2025051700361Fire Warning · false indicationAT 17,000 FEET WE GOT THE INDICATION OF APU FIRE. THE APU ENGINE FIRE SWITCH WAS PUSHED. THEN THE BOTTLE WAS DISCHARGED AND THE APU FIRE INDICATION WENT OUT. WE DECLARED AN EMERGENCY AND LANDED IN TETERBORO WHERE THE FIRETRUCKS FOLLOWED THE AIRPLANE AND THEN CSDR QMLA2025051520056Gearbox · warning lightMAIN ROTOR GEAR BOX CHIP INDICATOR LIGHT ILLUMINATED IN FLIGHT. FIRST SET OF FLIGHTS FROM CHANGING OF MBG OIL FILTER YESTERDAY.SDR DALA2025051603798Lens · missingAIRCRAFT 3409, 3L EMERGENCY EXIT SIGN LENS MISSING. CORRECTIVE ACTION: INSTALLED MISSING 3L EMERGENCY EXIT SIGN LENS IAW A33 AMM 33-51. (LP 7078696)SDR JGVR20250516001Support Bracket · corrodedREMOVED THE CORRODED MIDDLE LOWER RUDDER SUPPORT BRACKET, RECEIVED FABRICATED NEW BRACKET PART NUMBER AQRD-6931050-61 AND INSTALLED PER TEXTRON 680 SRM 51-40-03 AND AEROSPACE QUALITY RESEARCH AND DEVELOPMENT MRO ENGINEERING REPAIR ORDERSDR CVGA202505160126Clamp · detachedAIRCRAFT EXPERIENCED OVER TEMP AT START UP AND ABORTED TAKEOFF INSPECTED AIRCRAFT AFTER OVER TEMP CONDITION AND NOTICED R/H ENGINE BLEED LINE CLAMP SITTING IN COWLING .REVIEWED RECORDS AND FOUND THAT TEXTRON SMF PERFORMED THE CHECK 1 INSPECTION ON 5/6/2025.SDR JR2R20250516557Seal Rest · corrodedFWD CARGO CUTOUT, CENTER SEAL REST HAS CORROSION AT NUTPLATES. REPLACED.SDR JR2R20250516558Seal Rest · corrodedFWD CARGO CUTOUT, FWD SEAL REST HAS CORROSION AT NUTPLATES. REPLACED.SDR AALA202505160832Hose · out of positionAIRCRAFT WAS NOT GROUNDED: DURING A SCHEDULED REPLACEMENT OF THE L1 DOOR SLIDE RAFT ASSEMBLY MAINTENANCE FOUND THE SLIDE INFLATION HOSE WAS RUBBING ON THE ENCLOSURE AND COULD NOT BE REPOSITIONED. THE SLIDE / RAFT WAS DETERMINED TO BE BAD FROM STOCK, REMOVED FRSDR QXEA2025051600171Fadec · malfunctionedFLIGHT 9707. MSG " ENG 2 T2 HEAT FAIL " APPEARED WHILE PARKED AT GATE. PLACED ON MEL 73-21-17. MEL CLEARED 5/16 BY INTERROGATED CMC, FOUND FAULTS 73216217E2A AND 73216217E2B. PERFORMED E175 FIM 73-21-00-810-953-A WIRING CHECKS STEPS 6.AK-BC. NDN. REPLACED RELASDR 2025FA0000360Rivet · failedCARB AIRBOX BUTTERFLY VALVE ATTACHMENT TO ACTUATING SHAFT FAILED BY POORLY SHOT RIVET PULLING THROUGH THE BRACKET HOLE ON RIGHT SIDE. LEFT SIDE RIVET IS LOOSE AS WELL BUT HAD NOT FAILED AT THE TIME OF DISCOVERY. VALVE WAS HANGING DOWN AWAY FROM THE SHAFT. OWNESDR QR9R2025051600002Altimeter · failedABORTED TAKEOFF FOR RADAR ALTIMETER DID NOT DISPLAY ON ND OR PFD DURING RUN-UP. REMOVED AND REPLACED RADAR ALTIMETER IAW REF. COM/NAV 34-41-01. MOC SUCCESSFULLY COMPLETED.SDR QR9R2025051600001Sensor · faultyFAULTY TRIPLE TACHOMETER NR INDICATION WITH TWIST GRIPS IN FLIGHT (INTERMITTENT 101 TO 0 INDICATIONS WITH W/U DISPLAY AND AUDIO). REMOVED AND REPLACED NR SENSOR IAW AMM 62-41-00, 41. MOC OK.SDR JR2R20250516542Skin · chafedRH PYLON PANEL 419NR HAS MULTIPLE CHAFES AT SCREW HOLES. REPAIRSDR JR2R20250516451Skin · chafedRH PYLON PANEL 419ML HAS MULTIPLE CHAFES AT SCREW HOLES. REPAIRSDR JR2R20250516449Skin · chafedRH PYLON PANEL 429NR HAS MULTIPLE CHAFES AT SCREW HOLES. REPAIRSDR 2025FA0000359Deck Plate · corrodedFOUND CORROSION ON POTTY DECK LOWER SURFACE DURING 24MO INSPECTION. MEASURED, MAPPED, AND SUBMITTED POTTY DECK LOWER SURFACE CORROSION TO ENGINEERING FOR REPAIR DISPOSITION. REPAIR TOILET DECK SKIN AT LOWER SURFACE. PER: NETJETS RFTS-113845. FABRICATED AND INSSDR JR2R20250516559Skin · corrodedEXTERNAL SKIN AT LOWER SIDE OF FWD CARGO CUTOUT HAS 5 SPOTS OF CORROSION. REPAIRSDR JR2R20250516457Skin · chafedRH PYLON PANEL, 429ML, MULTIPLE CHAFES AT SCREW HOLES. REPAIRSDR FDEA202505160761Floor Panel · delaminatedREWORK:MAIN DECK CARGO COMPARTMENT AT STA 1940 FOUND CENTER FLOOR PANEL UPPER SURFACE HAVE SIGN OF DELAMINATED CONDITION. MEASURED MAIN DECK CARGO COMPARTMENT AT STA 1940 CENTER FLOOR PANEL UPPER SURFAE DELAMINATED DAMAGE SIZE LXW=4"X2.5" OUT OF ALLOWABLSDR KCSA202505161079Bulb · inoperativeAFT L1 DOOR SILL EMERGENCY LIGHT IS INOP.SDR CALA2025051604735Battery Pack · dischargedM/D R3 DOOR AFT EMERGENCY POWER SUPPLY M33401 BATTERY PACK FOUND LOW CAPACITY.