Service difficulty reports
1,773,593 reports of malfunctions and defects, newest first. Air carriers must report; general aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA2025050103351Bottle · low pressureSHIP 3102 DISC: R2 PAX DOOR EMERGENCY OPERATING CYLINDER/ACTUATOR REQUIRES SERVICING. C/A: SERVICED PER A319 AMM 52-10 ALTERNATE PROCEDURE. (LP: 6972937)SDR DALA2025050103349Floor Support · corrodedSHIP 3142 DISC: CORROSION LOWER SILL LOCATED AT FR 68 LH SIDE AT AFT GALLEY AREA (SSI 534147 ). C/A: PERFORMED REPAIR LOWER SILL LOC ON FR68 LH SIDE AT AFT GALLEY AREA AS PER A319 SRM 53-41-14-300-001 STEP 2, FIGURE 001, SHEET 4,PRINCIPLE 7 AND A319 SRM 51-42-SDR CALA2025050104394Warning Light · intermittentDURING TAXI OUT FWD CARGO DOOR OPEN INDICATION. MULTIPLE TIMES INTERMITENTLY VERIFIED FWD CARGO DOOR IS CLOSED AND LOCKED. APPROVED FOR MEL 5270J APPLIED MEL *DM* SUGGEST REF TSM 52-31-00-810-801-A FOR FURTHER ISOLATING THE FAULT. M/L UPDATED WITH PROX SW INSDR CALA2025050104384Bottle · not reportedOVER WING EMERGENCY ESCAPE SLIDE DEACTIVATION REF AMM 25-65-00-042-001. INSTALLED SAFETY PIN ON RIGHT OVERWING INFLATION CYLINDER REF AMM 25-65-00-042-001. PULLED CBS AND TAGGED K14, 15, 16 & 17 AND K17 & 18 ON P6. AS WELL AS C6, 7, 8, & 9; G17, 18, 26 & 27; PSDR CALA2025050104383Lock · faultedDOOR FLIGHT LOCK 2L EICAS STATUS #2 LEFT PASSENGER ENTRY DOOR FLIGHT LOCK COMMAND/FLT LK RLY/SENS OR DISAGREEMENT. PSEU 2 (L2) CURRENT FAULT IS ACTIVE. COMPLIED WITH DDP REF LOGPAGE 4621925, 2L DOOR LOCK ACTUATOR REPLACED STATUS MSG CLEARED.SDR ASAA2025042757572Lens · missingEXIT ROW PLACARD MISSING 16A. GROUNDED - YES. 16A EMERGENCY EXIT LIGHT LENS REPLACED W/ NEW OPS CHECKS OF LIGHTS GOOD REF AMM 33-51-01-960-801.SDR SWAA2025043064952Battery · no testAT FA JUMPSEAT FLASHLIGHT DOSE NOT TEST<[01] R AND R FLASH LIGHT BATTERY PER AMM 25-64-00SDR SWAA2025043064623Megaphone · brokenAFT MEGAPHONE BROKEN.<[01] REMOVED AND REPLACED AFT MEGAPHONE IAW AMM 25-64-00.SDR SWAA2025043064713Battery · inoperativeAFT LEFT HAND OUTBOARD FA FLASHLIGHT INOP<[01] REPLACED FLASHLIGHT BATTERY AT AFT L/H OTBD POSITION REF AMM 25-64-00SDR SWAA2025043064611Lamp · inoperativeR1 DOOR EMERGENCY EXIT SLIDE LIGHT INOP.<[01] RE-LAMPED SAID LIGHT ASSY PER AMM 33-51-04. OPS CHK OK.SDR SWAA2025043064961Sign · missingFORWARD SERVICE DOOR LOWER EXIT SIGN MISSING<[01] INSTALLED NEW EXIT SIGN PER AMM 33-51-01.SDR SWAA2025043064609Doubler · damagedEXTERNAL POWER CUTOUT LOWER AND AFT SECTION HAS SHARP EDGES<[01] REMOVED -1 DOUBLER AND -2 FILLER FROM PREVIOUSLY ACCOMPLISHED SRM 53-10-15-2R-4 REPAIR PER SRM 51-40-02.SDR SWAA2025043064610Doubler · crackedFOUND CRACK ON EGPR SURROUND DOUBLER FWD SIDE UNDER LOWER HINGE<[01] REPAIRED PER EA 25-153-01072; REF TTG8Q0103QYZ AND TTG8Q01048AL FOR WORK ACCOMPLISHED;[02] REPAIRED PER EA 25-153-01072; REF TTG8Q0103QYZ AND TTG8Q01048AL FOR WORK ACCOMPLISHEDSDR SWIA20250430027Pump · faultedHYD 3 LO PRESS AND GEAR DISAGREE. DID MANUAL GEAR EXTENSION AND HYD 3 QRH (FLIGHT 5539 - FILED CLOSED)FOUND HYDRAULIC PUMP 3A CRACKED, REMOVED AND REPLACED HYDRAULIC PUMP 3A WITH A SERVICEABLE UNIT IN REFERENCE TO AMM 29-12-03, NO LEAKS NOTED. PLEASE REFERENCSDR DALA2025043003344Fitting · jammedSHIP 5018 AFT GIRT BAR FLOOR FITTING JAMMED AT L1 DOOR. CORRECTIVE ACTION: REMOVED, REPLACED, AND ADJUSTED THE AFT GIRT BAR FLOOR FITTING AT L1 DOOR. REF A321 AMM 52-11-31 AND A321 AMM 52-11-00 (0936590)SDR DALA2025043003341Light · unknownSHIP 5047 EMERGENCY FLOOR LIGHTING DAMAGED OR INOPERATIVE. CORRECTIVE ACTION: OPERATED THE EMERGENCY LIGHTING AND COULD NOT DUPLICATE FAULT DISCREPANCY. OK FOR SVC (0936430)SDR DALA2025043003337Slide · faultedSHIP 3006 DURING SVC EMER LIGHT TEST FAILED ESCAPE SLIDE LT/EPSU 13WL AFT L. CORRECTIVE ACTION: REMOVED AND REPLACED L4 DOOR SLIDE REF AMDS WORK CARD 2561-400- LA (6540909)SDR DALA2025043003336Bleed Air Sys · odor800 FT ON APPROACH FO SMELLED DIRTY SOCK ODER , 500 FT CA SMELLED IT AS WELL.APU WAS STARTED ONCE LANDED .R BLEED TURNED OFF SMELL DISAPPEARED. DUCT BURNOUT C/ W AGAIN WITH RT ENG PER AMDS CARD 0550-2008.LT ENG BLEED LOCKED BACK PER AMP 36-11 AS NOTED IN LOG #SDR DALA2025043003334Bottle · low pressureL2 DOOR EMERGENCY OPENING ASSIST MEANS PRESSURE LOW (RED RANGE). SERVICED L2 EMERGENCY DOOR OPENING ASSIST IAW A220 AMP BD500- A-J52-12-08-01AAA-214B-A. (LP# 0936752)SDR DALA2025043003333Seat Track · corrodedSEAT TRACK AT FR 74 LBL 43.5 HAS EVIDENCE OF CORROSION ON TRACK LUG AFT OF LAV MOUNT. SCEPTRE LOG PAGE ENTERED FOR SDR REPORTING. SUMMARY SEE NR FOR ADDITIONAL INFORMATION 069-0001:5331-01297-02B/006 00322 COMPLIED WITH ER/A 623167-14TR REV ORIGINAL. (LP# 0936SDR DALA2025043003332Seat Track · corrodedSEAT TRACK AT FR 74 LBL 23 HAS EVIDENCE OF CORROSION ON TRACK LUG AFT OF LAV MOUNT. SCEPTRE LOG PAGE ENTERED FOR SDR REPORTING. SUMMARY SEE NR FOR ADDITIONAL INFORMATION 069-0001:5331-01297-02B/007 00323 COMPLIED WITH ER/A 623168-14TR REV O. SCEPTRE LOG PAGE ESDR DALA2025043003331Skin · corroded***CORROSION*** FWD CARGO DOOR CUTOUT, UNDER SCUFF PLATES, AT HOLES 80U AND 20OL (MARKED). WORK ACCOMPLISHED ON ER/A 625727-14 REV-ORIGINAL. SECTION 1-2-3 ASSOCIATED ER/A 14-625727 ADDED FOR AC 8113. (LP# 0936219)SDR DALA2025043003330Door Sill · corroded***CORROSION*** ON FWD CARGO COMPARTMENT DOOR LOWER SILL FASTENER HOLES, BETWEEN FR-24 AND FR-29. WORK ACCOMPLISHED ON ER/A 625727-14 REV-ORIGINAL SECTION 1-2-3. (LP# 0936112)SDR 6CBA2025042704001Unknown · odorDURING CRUISE AT 26000 FT IN VFR CONDITIONS, THE CREW REPORTED A BURNING OIL ODOR IN ACS SYSTEM. AN EMERGENCY DECLARED AND THE CREW DIVERTED TO KBWI. OXYGEN WAS USED BY THE CREW AND PASSENGER AT THIS TIME. LANDING WAS UNEVENTFUL. NO ABNORMAL ENG INDICATIONS ORSDR DALA2025043003311Sign · missingTHE EMERGENCY EXIT "RUNNING MAN" OVERHEAD SIGN AT ROW 20 IS MISSING. MAINTENANCE ROBBED A REPLACEMENT SIGN FROM A/C 1702 AND INSTALLED AT ROW 20. OPERATIONAL CHECK WAS GOOD. WORK DONE PER B767 AMM 33-22. (LP #6862734)SDR DXTA2025043003248Pdu · faultedFLAPS FAIL AMBER CAS: FLAPS FAIL SELECTING FLAPS 2. RAN CHECKLIST AND FAILED AGAIN AFTER USING FLAP RESET. CORRECTIVE ACTION: PERFORMED FLAP SYSTEM TROUBLESHOOTING, FOUND BITE 2 FAULT CODE ON FLAP CONTROLLER. DETERMINED THAT FLAP PDU REQUIRES REPLACEMENT. ALLSDR CALA2025043004356Proximity Sensor · out of adjustDOOR FWD CARGO EICAS CAUTION FORWARD CARGO DOOR NOT FULLY CLOSED, LATCHED AND LOCKED. PSEU 2 (R2) ADJUSTED LATCHED PROXIMITY SENSOR 552042 AND LOCKED PROXIMITY SENSOR 552022 ON FWD CARGO DOOR REF AMM 52-34-20. ACCOMPLISHED PROXIMITY SENSOR TEST REF AMM TASK SDR CALA2025043004352Blower · faultedVENT BLOWER FAULT DISPLAYED IN THE UPPER ECAM SCREEN TECH SUOV UPDATE DURING TAXI TEST WHILE THE NUMBER 1 GEN WAS FLUCTUATING THE VENT BLOWER CIRCUIT BREAKER TRIPPED AND WOULD NOT RESET PLEASE INSPECT CONTACTOR 8HQ FOR ANY SIGNS OF BURNING PERFORMED INSPECTIONSDR CALA2025043004351Pitot Tube · faultedFEEL DIFF PRESS LIGHT ILLUMINATED AFTER TAKEOFF INSP A/C FOUND NO FAULTS LOGGED. REF FIM 27-31 TASK 803 ACCOMPLISHED FIM TO PARA C STEP 1. REF AMM 27-31-00-700-812 FEEL DIFFERENCIAL PRESSURE LIGHT TEST, TEST PASSED. NEED TO CONTINUE FIM 27-31 TASK 803 WITH PARSDR CALA2025043004350Pressure Switch · faultedDEBRIEFED CREW, NO OVWT LANDING, 32K FEET, FUEL FILTER BYPASS R MSG, ENG APPEARED AND SHOWED NORMAL, ALL INDICATIONS NORMAL. 2 HRS OUT. ADVISORY TO STATUS. 304-283-6970. PILOT. REMOVED AND REPLACE #2 ENGINE FUEL FILTER REF AMM 73-11-02-404-008-H00, LEAK CHECK SDR CALA2025043004347Fuel Cap · missingPDA 2 FUELERS REPORTED FUEL CAP MISSING. NOTIFIED TOMC CONTROLLER JAY NEWMAN APPROVED CDL FOR FUEL CAP MISSING.REF LOG PAGE 4650533. INSTALLED UNDERWING FUEL CAP REF AMM 28-25-41-400-005SDR CALA2025043004346Unknown · odorCREW REPORTED STRONG DIRTY SOCK SMELL IN FLIGHT DECK ONLY ON DESCENT. OCCURRED AT 8,000' LASTED ABOUT THREE MINUTES. CABIN CREW REPORTED NO FUMES OR DIRTY SOCK SMELL. NOTICED ODOR WHEN INCREASING POWER FROM IDLE, ONLY IN-FLIGHT DECK. PERFORMED INSPECTION RESDR CALA2025043004345Filter · dirtyCABIN AIR FILTER CHANGE NUMEROUS REPORTS OF ALLERGY RELATED SYMP TONS SPOKEN WITH INBOUND CREW, REPORTS OF SOME CREW MEMBERS REPORTING HAY FEVER RELATED SYMPTOMS. NO MEDICAL REPORTS FILED. RUN BOTH PACKS INDIVIDUALLY AND TOGETHER FOR 30/45 MINS NO FAULTS NOTEDSDR CALA2025043004340Door · noneBATHROOM DOOR 2R JAMMED. FOUND LAV E OPENING AND CLOSING NORMAL. ALSO CHECKED LAV D AND A DOORS. ALL OPERATING NORMAL. FOUND LAV E OPENING AND CLOSING NORMAL. ALSO CHECKED LAV D AND A DOORS. ALL OPERATING NORMAL.SDR CALA2025043004339Liner · not reportedAFT ENTRY DOOR 2, EXCAPE SLIDE REMOVED FOR DOOR LINING REMOVAL, REF TASK 25-66-01-000-801 REF W/UP. 4640047. SLIDE IS NEAR DOOR 2, RIGHT. REINSTALLED DOOR 2LH EXCAPE SLIDE AMM 25-66-01 CK OK RII C/W. VERIFIED INSTALLATION OF L2 DOOR SLIDE PER ESCAPE SLIDE PACKSDR CALA2025043004338Seal · fodR2 DOOR UPPER FWD AND AFT CORNERS HAS AUDIBLE AIR LEAKAGE FOUND DEBRIS IN DOOR JAM AREA, CLEANED OFF DEBRIS LEAK CHECK STILL NEEDED PRESSURIZED CABIN, LEAK CHECKED R2 DOOR , NO LEAKS NOTED ALL IS GOOD REF AMM 05-51-91-790-801.SDR YENA2025042900454Power Supply · no testDURING HEAVY MAINTENANCE: EPSU 10WL FAILED OPS CHECK; REF STS NR W003804 N0277 - R & R EPSU BATTERY 10WL IAW AIRBUS AMM 33-51-000-002-A/400-001-A. OPS CKS GOOD IAW AMM 33-51-00-710-001A & 23-73-00-740-005.SDR YENA2025042900453Power Supply · no testDURING HEAVY MAINTENANCE: EPSU 12WL FAILED OPS CHECK; REF STS NR W003804 N0277 - R & R EPSU BATTERY 12WL IAW AIRBUS AMM 33-51-000-002-A/400-001-A. OPS CKS GOOD IAW AMM 33-51-00-710-001A & 23-73-00-740-005.SDR YENA2025042900452Power Supply · no testDURING HEAVY MAINTENANCE: EPSU 13WL FAILED OPS CHECK; REF STS NR W003804 N0277 - R & R EPSU BATTERY 13WL IAW AIRBUS AMM 33-51-000-002-A/400-001-A. OPS CKS GOOD IAW AMM 33-51-00-710-001A & 23-73-00-740-005.SDR YENA2025042900451Power Supply · no testDURING HEAVY MAINTENANCE: EPSU 14WL FAILED OPS CHECK; REF STS NR W003804 N0277 - R & R EPSU BATTERY 14WL IAW AIRBUS AMM 33-51-000-002-A/400-001-A. OPS CKS GOOD IAW AMM 33-51-00-710-001A & 23-73-00-740-005.SDR YENA2025042900450Power Supply · no testDURING HEAVY MAINTENANCE: EPSU 15WL FAILED OPS CHECK; REF STS NR W003804 N0277 - R & R EPSU BATTERY 15WL IAW AIRBUS AMM 33-51-000-002-A/400-001-A. OPS CKS GOOD IAW AMM 33-51-00-710-001A & 23-73-00-740-005.SDR SWAA2025042964957Transmission · faultedTRAILING EDGE FLAP DISAGREE ON FINAL<[01] DRAINED & SERVICED TRAILING EDGE FLAP TRANSMISSION N0 .1 AND N0 .8. PERFORMED OPS CK. OPS CK OK REF AMM 12-22-51SDR DALA2025042903309Sign · damagedSHIP 5806 EMERGENCY EXIT SIGN LIGHT AT DOOR 1R DAMAGED. CORRECTIVE ACTION: REPLACED EXIT SIGN ASSY PER B757 AMM 33-51 OPS CHECKS GOOD. (6873457)SDR AALA202504295150Module · faultyAIRCRAFT WAS GROUNDED: NUMBER 1 ENGINE LOW OIL PRESSURE. 28-30 PSI AT 93.6N2. RETURNED TO DFW, DID NOT DECLARE EMERGENCY. FOUND CLASS 3 FAULTS FOR OIL PRESS XMTR 1 (4003EN) OR LOW PRESS1 SW (4001EN) IN #1 EIU HITTING OVER THE LAST FEW DAYS. UPON INITIAL INSPECSDR AALA202504294493Unknown · odorAIRCRAFT WAS GROUNDED: ELECTRICAL ODOR IN FLIGHT DECK STARTED WHILE CLIMBING THROUGH 8000 FEET SMELL CONTINUE THRU LANDING. BURNING IN EYES. HAZE WAS NOTED IN COCKPIT. FLIGHT RETURNED TO DFW AND LANDED OVERWEIGHT WITHOUT INCIDENT. MAITNENANCE COULD NOT REPRODSDR VNAA2025042911101Overheat Loop · faultedL BLEED DUCT WARNING MSG / REMOVED AND REPLACED LH BLEED LOOP A WIRE AND CONNECTORS FROM MT139P1 TO MT141P1 WITH NEW INSULATORS AS AN ASSY ROBBED FROM N534AE IAW FIM 36-21-01-810-801-A01. OPS CHECKS GOOD. LH BLEED LOOP A CHECKS AT 66 OHMS.SDR A6WA202504028867Adc · faultedAT 28000 FT DURING DECENT F/O AIRSPEED DECREASING AND EFIS COMP MON IAS CAUTION PRESENT AT 16000 FT F/O AIRSPEED RETURNED TO NORMAL. REMOVED AND REPLACED #2 ADC. OPS CHECK AND LEAK CHECK GOOD AT THIS TIMESDR CALA2025042904322Battery Pack · no testEMERGENCY LIGHTING SYSTEM FUNCTIONAL CHECK- FAILED AT THE FOLLOWING 6QTY BATTERY PACK LOCATIONS: M1669, M1670, M1672, M1673, M1674 AND M1675. REPLACED EMERGENCY LIGHT BATTERY PACKS LOCATED AT : #M1669, M1670, M1672, M1673, M1674 AND M1675 IN REFERENCE TO MM #3SDR CALA2025042904308Test Switch · brokenEMERGENCY LIGHTS - OPERATIONAL TEST WITH THE TEST SWITCH PROCEDURE - COCKPIT EMERGENCY LIGHTS SWITCH BROKEN RAR BROKEN SWITCH GUARD 402-112 REF AIPC 33-51-08-03 ITEM 20. EMERGENCY LIGHTS FUNCTION NORMALLYSDR CALA2025042904307Spring · brokenEMER LIGHTS GUARD SPRING BROKEN REPLACED FLIGHT DECK EMERGENCY LIGHT TOGGLE SWITCH GUARD REF IPD DMC-B787-A-23-24-04-010-941A.PARTS USED: 79-3041-3-0002, QTY :1