What was found
FEEL DIFF PRESS LIGHT ILLUMINATED AFTER TAKEOFF INSP A/C FOUND NO FAULTS LOGGED. REF FIM 27-31 TASK 803 ACCOMPLISHED FIM TO PARA C STEP 1. REF AMM 27-31-00-700-812 FEEL DIFFERENCIAL PRESSURE LIGHT TEST, TEST PASSED. NEED TO CONTINUE FIM 27-31 TASK 803 WITH PARA C STEP 2. PERFORMED RH ELEVATOR PITOT REMOVED DUE TO BLOCKAGE REF APPLICABLE STEPS AMM 27-31-67- TEST SET HOSES INSTALLED, DRAINS REMOVED FROM ELEVATOR FEEL COMPUTER LINES. PLUGS INSTALLED ON DIAPHRAGHM FITTINGS AND LINES. PERFORMED ELEV PITOT LEAK CHECK, LEAK CHECK PASSED RR RH ELEVATOR PITOT PROBE REF AMM 27-31-94 REQUIRES OPS CKS. RH ELEV. PITOT OPS CHECKS GOOD.