Service difficulty reports
1,773,593 reports of malfunctions and defects, newest first. Air carriers must report; general aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR FXTA20250410001Hub · leakingPROP INSTALLED AND RED OIL NOTED LEAKING FROM PROP BLADE ROOTS AFTER GROUND RUNS. FOLLOWED MANUFACTURES TROUBLESHOOTING AND LEAK CONTINUED. CLEANED/DRIED AND LET SIT OVERNIGHT. FOUND OIL LEAKING FROM BLADE #4 NEXT MORNING WITH PROP STATIC. "0" ENTER FOR PROPSDR DXTA2025040903016Power Supply · inoperativeEMERGENCY LIGHTING: ONE WHITE EMERGENCY FLOOR PATH LIGHT IS INOP BENEATH THE CREDENZA, ONE BENEATH THE DIVAN AND ONE BENEATH SEAT 14. CORRECTIVE ACTION: REMOVED AND REPLACED WITH NEW EMERGENCY UGHT POWER SUPPLY I/A/W GL7500 AMM 33-53-13. OPS CHECK GOOD.SDR DXTA2025040903018Handle · out of adjustWHEN CLOSING MAIN DOOR FROM INSIDE CABIN DOOR OPEN CAS AND AMBER DOOR OPEN LIGHT DOESN'T EXTINGUISH UNLESS DOOR HANDLE IS PUSHED DOWN. WHEN OPENING DOOR FROM INSIDE, PUSHING RED THUMB BUTTON DOESN'T ACTIVATE THE HANDLE UNLESS HANDLE IS 1ST PUSHED DOWN. CORRECTSDR AALA202504108041Battery · inoperativeAIRCRAFT WAS GROUNDED: WHILE PERFORMING THE EMERGENCY LIGTHING SYSTEM OPERATION CHECK FOUND SEAT 22H, 25D, 25H & 26H EMERGENCY LIGHT INOP PER WORK CARD 78T21033001. MAINTENANCE REMOVED AND REPLACED WBU 21 IAW AMM 33-51-07.SDR AALA202504104938Wire · damagedAIRCRAFT WAS GROUNDED: WHILE PERFORMING THE EMERGENCY LIGTHING SYSTEM OPERATION CHECK FOUND SEAT 20H EMERGENCY LIGHT INOP PER WORK CARD 78T21033001. MAINTENANCE FOUND DAMAGED WIRE UNDER SEAT 20H, RETERMINATED WIRE AT EMERGENCY LIGHT UNDER SEAT 20H,SDR AALA202504105020Accumulator · low pressureAIRCRAFT WAS NOT GROUNDED: AFT L/H PASSENGER/CREW DOOR EMERGENCY CYLINDER ACCUMULATOR REQUIRES SERVICING (READS 650PSI AT 41 DEGREES FAHRENHEIT). SERVICED AFT L/H PASSENGER/CREW DOOR AS REQUIRED TO 1650PSI AT 41 DEGREES FAHRENHEIT IAW AMM 52-10-00.SDR 454A250410924411Elec Connector · dirtyRIGHT TRANSMISSION PRESSURE INDICATOR TURNED RED AND WENT DOWN TO 0, PIC DECLARED AN EMERGENCY TO WILMINGTON TOWER. PIC WENT INTO HOVER AND THE ALERT WENT BACK TO NORMAL FOR A MOMENT THEN WENT RIGHT BACK TO RED. PILOT LANDED SAFELY IN A FIELD, COMS CANCELED EMSDR SCNA20250410109Wire Harness · crossedWORK ORDER 94469, NR00004: 15 ABC EMERGENCY EXIT LIGHT INOP. - RESOLUTION: REMOVED AND REPLACED 15 ABC EMERGENCY EXIT LIGHT AND FOUND THE WIRING HARNESS CROSSED.SDR IXXA20250410017Target · faultedPRIOR TO APPROACH, LE SLAT ASSYMETRY DISPLAYED WITH FLAPS EXTENDED BEYOND 20 CREW DECLARED AN EMERGENCY LANDING TO KCLT AIR TRAFFICE CONTROL. LANDING WAS WITHOUT INCIDENT AND NO ADDITIONAL PRECAUTIONARY ACTIONS. ON ARRIVAL, THE AIRCRAFT WAS GROUNDED FOR MAINTSDR CALA2025041003674Battery · no testEPSU BATTERY FWD L MESSAGE ON EMERGENCY LIGHTS TEST REMOVED AND REPLACED ESPU BATTERY REF AMM 33-51-38. OKAY FOR SERVICE.PARTS USED: 18-3351-3-0001,QTY :1SDR CALA2025041003673Battery Pack · no testR.H. MID. EMERG LIGHT BATT. IS NOT TESTING. REMOVED AND REPLACED EMERG BATT. PACK AT R.H. MID. LOCATION. OPS. CHECK NORMAL. REF AMM 33-51-38-400-002-ASDR CALA2025041003672Battery Pack · dischargedEMERGENCY LIGHT BATTERY PACK M1674 FAILS CAPACITY CHECK..EMERGENCY LIGHTING SYSTEM FUNCTIONAL CHECK (INTERIOR AND EXTERIOR) {MULT-33-3-0004} - REPLACED EMERG. BAT. AT #M1674, OPS CHK GOOD, PER MM #33-51-06-960-805.PARTS USED: 99-3351-3-0015,QTY :1SDR N6WA2025041001Bulkhead Web · corrodedCORROSION ON LH AND RH INBD AFT FACE OF FS280 BULKHEAD WEB AT FLOOR LEVEL. PERFORMED INSPECTION OF RH INBD AFT FACE ON FS280 BULKHEAD WEB AND FOUND TO BE WITHIN LIMITS IAW CRJ SRM 51-12-00. PERFORMED REPAIR ON LH INBD AFT FACE OF FS280 BULKHEAD WEB IAW CRJ SSDR HNAA2025040800197Engine · bird ingestionBIRD STRIKE ON #2 ENGINE. #2 ENG CHANGE. SEE W/C 71-00-00 ON WORK PACKAGE.SDR CALA2025041003666Fuse · blownROW 22 TO 35 SEAT EMERGENCY EXIT LIGHTS NOT WORKING. CONTINUED TROUBLESHOOTING AND FOUND EMERGENCY BATTERY POWER SUPPLY M2626 NOT PERFORMING AUTOTEST WITH THE MANUAL BUTTON. SLAVED IN EMERGENCY BATTERY FROM ANOTHER POSITION, STILL DOES NOT WORK. REPLACED FUSE SDR N6WA2025040904Seat Track · corrodedCORROSION ON RH FLOOR SEAT RAIL BETWEEN FS349 - FS485. REMOVED AND REPLACED RH FLOOR SEAT RAIL FROM FS349 - FS485 IAW CRJ AMM 53-00-49.SDR N6WA2025040903Frame · corrodedCORROSION AT FS501 BETWEEN STRINGER 24L - STRINGER 25L. PERFORMED FRAME FLANGE REPAIR AT FS501 BETWEEN STRINGER 24L - STRINGER 25L IAW CRJ SRM 53-00-06.SDR N6WA2025040902Seat Track · corrodedCORROSION ON THE RH FLOOR SEAT RAIL BETWEEN FS469 - FS545. REMOVED AND REPLACED THE RH FLOOR SEAT RAIL BETWEEN FS469 - FS545 IAW CRJ SRM 51-40-11.SDR N6WA2025040901Frame · corrodedCORROSION ON FRAME AT FS310 BETWEEN STRINGER 25R AND STRINGER 25L. PERFORMED REPAIR ON FRAME AT FS310 BETWEEN STRINGER 25R AND STRINGER 25L IAW GOJET EO C550-53MR-049 REV O.SDR JR2R20250409915Panel · chafedRIGHT HAND PYLON PANEL, 429NR, INNER SURFACE, HAD MULTPLE AREAS OF CHAFING THAT ARE OUT OF LIMITS.SDR QR9R2025040900002Transducer · faulty#1 TRANSMISSION OIL PRESSURE DROPPED BELOW 1.0 BAR DURING TAKEOFF. REMOVED AND REPLACED TRANSDUCER IAW AMM 63-41-00, 4-4. MOC COMPLETED, NO FLUCTUATIONS OR ANOMALIES NOTED.SDR QR9R2025040900001Sensor · faultyLOW ROTOR RPM LIGHT ON THE WU WITH ASSOCIATED TONE CAME ON INADVERTANTLY 6 TIMES DURING A 30 MINUTE FLIGHT. DURING TROUBLESHOOTING OF MAIN ROTOR RPM SYSTEM, FOUND RPM MONITORING SYSTEM TO BE WORKING. RPM SENSOR IS AT FAULT. REMOVED AND REPLACED SPEED PICK-UP (SDR AALA202504095201Door · draggingAIRCRAFT WAS NOT GROUNDED: LAVATORY-D DOOR DIFFICULT TO OPEN AND CLOSE. FOUND SCUFF PLATE AT LAVATORY-D DAMAGED AND DOOR DRAGGING. (OPEN).SDR IPXA2025040901975Test Switch · inoperativeCREW REPORTS R/1 DOOR EVAC SLIDE REMOTE PRESSURE PRESS TO TEST SWITCH INOP. PERFORMED OPS CK PER AMM 25-61-04. COULD NOT DUPLICATE PROBLEM AT THIS TIME. BOTTLE CHARGE IS SATISFACTORY AT THIS TIME. DMP REVERSED, PLACARD REMOVED.SDR FDEA202504090584Door · out of alignmentWHILE ATTEMPTING TO DISARM L1, RAMP PERSONNEL WAS ATTEMPTING TO OPEN L1 DOOR BEFORE THE SLIDE WAS ABLE TO BE DISARMED. MECHANICAL DISARM FEATURE WAS UNABLE TO MOVE TO DISARM POSITION, SLIDE FELL OUT OF DOOR WITH NO (INTENDED) DEPLOYMENT. RELEASED FOR SERVSDR DALA2025040902766Bottle · low pressureSHIP 3411 4R DOOR ASSIST LOW. CORRECTIVE ACTION: SERVICED DOOR ASSIST BOTTLE PER A330 AMM 52-15. (7129388)SDR DALA2025040902765Sign · detachedSHIP 3309 EMERGENCY SEAT MOUNTED LIGHTING DAMAGED AT SEAT 57H. CORRECTIVE ACTION: RE-ATTACHED EMERGENCY EXIT SIGN LIGHT TO SEAT 57H AND CHECKED OK. (0903295)SDR DALA2025040902763Wire · damagedSHIP 3309 FLOOR PROX EMERG LIGHT AT 46H INOP. CORRECTIVE ACTION: REPAIRED WIRING PER A330 AMM 33-52. (6411729)SDR 2025FA0000257Fuel Cell · fodWHILE ACCOMPLISHING SL 700-28-02, A RAG WAS FOUND IN THE RIGHT WING FUEL BAY NUMBER 13 FLAPPER. THIS WAS THE FIRST INSPECTION OF THE FUEL STORAGE SYSTEM SINCE PRODUCTION.SDR WRXR20250409005Access Panel · chafedGOUGING ALONG ELECTRICAL BONDING SURFACE OF RH WING O/B FUEL PANEL 651BB. BLENDED OUT GOUGE IAW CRJ 900 SRM 51-12-00-001-001-A01. COMPLIED WITH REO 690-57-22-100 REV -- DATE: 2025-04-07.SDR WRXR20250409004Access Panel · chafedGOUGING ALONG ELECTRICAL BONDING SURFACE OF LH WING O/B FUEL PANEL 551EB. PERFORMED BLENDING ON PANEL 551EB IAW CRJ 900 SRM 51-12-00-001-001-A01. COMPLIED WITH REO 690-57-22-098 REV -- DATE: 2025-04-07.SDR WRXR20250409003Access Panel · chafedGOUGING ALONG ELECTRICAL BONDING SURFACE OF LH WING O/B FUEL PANEL 551DB. BLENDED OUT GOUGE IAW CRJ 900 SRM 51-12-00-001-001-A01. COMPLIED WITH REO 690-57-22-099 REV -- DATE: 2025-04-07.SDR WRXR20250409002Access Panel · gougedGOUGING ALONG ELECTRICAL BONDING SURFACE OF RH WING O/B FUEL PANEL 651AB. BLENDED OUT GOUGE IAW CRJ 900 SRM 51-12-00-001-001-A01. COMPLIED WITH REO 690-57-22-101 REV -- DATE: 2025-04-07.SDR WRXR20250409001Access Panel · gougedGOUGING ALONG ELECTRICAL BONDING SURFACE OF LH WING O/B FUEL PANEL 551FB. PERFORMED BLENDING ON PANEL, COMPLIED WITH REO 690-57-22-097 REV -- DATE: 2025-04-07.SDR DALA2025040902760Repair · misinstalledFASTENER DISCREPANT INSTALLATION ON PREVIOUS FUSELAGE SKIN REPAIR, ALSO THERE ARE LIGHTNING STRIKES AT TWO LOCATIONS ADJACENT TO REPAIR FASTENERS AT AFT LH ALTERNATE STATIC PORT AREA BTW STA Y=256-362 AND BTW LONG 26LH-27RH. SUMMARY OF NRC 00664: FASTENER DISCSDR DALA2025040902761Web · corrodedWEB FOUND CORRODED LHS OF Y CHORD AT STA 1053. SUMMARY SEE NRC 001-0575:5300-2013/027 01414: REPAIRED WEB REF B717 SRM 51-70-10-2R REPAIR 1. (LP #0903790)SDR SWI2025F01252Skin · crackedPAX DOOR SKIN CRACKED AT PAX DOOR PANEL 832AL CUT OUT DURING INSTALL OF FWD PULL IN LEVER (MARKED) (C-CHECK RO 09/07/2025)REPAIRED PAX DOOR SKIN CRACKED AT PAX DOOR PANEL 832AL CUT OUT. PER REO 690-52-11-1033 REV -- DATE 2025-05-19. SEE CONTINUATION TASK FOR SDR SWIA2025090900408Support Angle · corrodedMULTIPLE CORRODED FASTENERS, LH OUTBOARD TRAILING EDGE, LOWER SUPPORT ANGLE. SEE ATTACHED PICS. (C-CHECK RO 09/07/2025)REMOVED AND INSTALLED NEW CHANNEL CC670-17224-1 REF. CRJ 900 SRM 51-42-06-001-001-A01, 51-42-28-001-001-A01, AND DWG CC670-17227 REV. B. SESDR SWI2025F00971Door Frame · corrodedAVIONICS BAY DOOR SURROUND DOOR CUTOUT BETWEEN FS364.00 €“ FS394.00 AND STRGR25R €“ STGL25L HAS MULTIPLE SPOTS OF CORROSION (MARKED) (C-CHECK RO 07/16/2025)REPAIRED AVIONICS BAY DOOR SURROUND CUTOUT BETWEEN FS360-FS394 AND STGR25R-STGR25L REF REO 690-53-21-SDR SWIA2025071700408Door · crackedR/H AFT EMERGENCY EXIT DOOR HAS CRACKED NEXT TO AFT HOOK FITTING (MARKED) (C-CHECK RO 07/16/2025)REPAIRED CRACK ON THE R/H AFT EMERGENCY EXIT DOOR, NEXT TO AFT HOOK FITTING REF REO 670-52-21-103 REV--, DATED 2024-11-06, COMPLIED WITH ALL STEPS. COMPLIED WITH SDR NACA2025040800008Skin · debondedRH WING OUTBOARD AFT FLAP LOWER SKIN DISBOND BETWEEN WBL.270~WBL.280. PERFORMED CATEGORY A METAL BOND REPAIR WITH 250 F CURE MATERIAL AT RH WING OUTBOARD AFT FLAP LOWER SKIN BETWEEN WBL 270-WBL 280 IAW B737-300 SRM 57-53-02 REPAIR 2 & SRM 51-70-10 REPAIR 4 (R1SDR SWI2025F00785Rod · damagedRH INBD FLAP HAS GROOVE ON FLAP VANE ACTUATOR ROD AT APPROX FLS 102.90. (C-CHECK RO 06/29/2025)RH INBD FLAP VANE ACTUATOR ROD AT APPROX FLS 102.90. REPAIRED PER REO 670-57-52-257, REV -A, DATE 2024-08-20. WITHIN LIMITS. OPERATIONAL TEST PASSED. COMPLIED WITHSDR SWI2025F00784Fitting · chafedRH FWD EMERGENCY EXIT DOOR I/B AND O/B HOOK FITTINGS CHAFFED. CAMP # 29942099. (C-CHECK RO 06/29/2025)PERFORMED BLEND OUT REPAIR ON RH FWD EMERGENCY EXIT DOOR I/B AND O/B HOOK FITTINGS. REF. REO 690-52-21-192 REV.-- DATED 2025-04-21. COMPLIED WITH TASK CARD SDR SWI2025F00783Rod · groovedRH INBD FLAP HAS GROOVE ON FLAP VANE ACTUATOR ROD AT APPROX FLS 140.40. (C-CHECK RO 06/29/2025)RH INBD FLAP VANE ACTUATOR AT APPROX FLS 140.40 REPAIRED PER REO 670-57-52-257, REV -A, DATE 2024-08-20. WITHIN LIMITS. NO DEFECTS. COMPLIED WITH M-337 AND TASK CASDR SWI2025F00782Rod · damagedRH INBD FLAP VANE ACTUATOR AT APPROX FLS 24.00 HAS A GROOVE ON THE ACTUATOR ROD. (C-CHECK RO 06/29/2025)RH INBD FLAP VANE ACTUATOR AT APPROX FLS 24.00 REPAIRED PER REO 670-57-52-257, REV -A, DATE 2024-08-20. WITHIN LIMITS. NO DEFECTS. COMPLIED WITH M-337 ANSDR SWI2025F00781Frame · corrodedCORROSION FOUND ON FRAME FS533.00 BETWEEN STGR 17L AND 18L WEB PORTION AND ATTACHING FLANGE. (29941771) (C-CHECK RO 06/29/2025)PERFORMED SPLICE REPAIR ON FRAME FS533.00 BETWEEN STGR 17L AND 18L. REF CRJ-900 SRM 53-00-06-201-001-A03, CRJ-900 SRM 51-42-06-001-SDR SWI2025F00780Rod · groovedRH INBD FLAP HAS GROOVE ON FLAP VANE ACTUATOR ROD AT APPROX FLS 65.50. (C-CHECK RO 06/29/2025)RH INBD FLAP VANE ACTUATOR ROD AT APPROX FLS 65.50 REPAIRED PER REO 670-57-52-257 REV-A DATE 2024-08-20. WITHIN LIMITS. OPERATIONAL TEST PASSED. COMPLIED WITH M-337 SDR SWI2025F00779Angle · corrodedANGLE FOR LH TIRE BURST PANEL 542AZ IS CORRODED. (C-CHECK RO 06/29/2025)REMOVED AND REPLACED LH TIRE BURST PANEL 542AZ ANGLE REF CRJ900 SRM 51-42-21-001-001-A01 REVISION 38,DATED JULY 25/2020 AND DWG CC670-10320 REV FCOMPLIED WITH SKYWEST TASK CARD 51-900-100SDR SWI2025F00778Fitting · chafedRIGHT AFT EMERGENCY EXIT DOOR I/B AND O/B HOOK FITTINGS CHAFFED. PERFORMED BLEND OUT REPAIR ON RH AFT EMERGENCY EXIT DOOR I/B AND O/B HOOK FITTINGS. REF. REO 690-52-21-193 REV.-- ISSUED 2025-04-21.COMPLIED WITH TASK CARD 51-900-1002-SKY.SDR SWI2025F00777Fitting · chafedLH AFT EMERGENCY EXIT DOOR I/B AND O/B HOOK FITTINGS CHAFFED. CAMP # 29942073. (C-CHECK RO 06/29/2025)PERFORMED BLEND OUT REPAIR ON LH AFT EMERGENCY EXIT DOOR I/B AND O/B HOOK FITTINGS. REF REO 690-52-21-194 REV -- DATED 2025-04-21. COMPLIED WITH TASK CARD 51