This text is OCR from a scan. OCR can misread letters and numbers. © Airbus S.A.S. Filed by the FAA in regulations.gov docket FAA-2011-0388; AD 2011-16-03 incorporates this document by reference. Not covered by OpenAirDocs’ CC0 dedication.
Query with SQL
duckdb -csv -c "SELECT p.page, p.text_source, p.text, f.rights_holder, f.license FROM 'https://openairdocs.org/data/latest/service_document_file_page.parquet' p JOIN 'https://openairdocs.org/data/latest/service_document_file.parquet' f USING (file_sha256) WHERE p.file_sha256 = '81836737e23d662c63e74346ac415f7465b8b8c0655923964b9c38c935fff365' ORDER BY p.page"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT p.page, p.text_source, p.text, f.rights_holder, f.license FROM 'https://openairdocs.org/data/latest/service_document_file_page.parquet' p JOIN 'https://openairdocs.org/data/latest/service_document_file.parquet' f USING (file_sha256) WHERE p.file_sha256 = '81836737e23d662c63e74346ac415f7465b8b8c0655923964b9c38c935fff365' ORDER BY p.page
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
ALL OPERATORS TELEX - ALL OPERATORS TELEX SUBJECT: ATA29 - RAM AIR TURBINE - SCREW REPLACEMENT OUR REF: AOT A300-29A6062 dated 01 SEP 2009
1. AIRCRAFT AFFECTED This AOT applies to all A300-600 in service aircraft equipped with Hamilton Sundstrand Ram Air Turbine (RAT) Turbine Assembly PN 734350 series.
For A300-600 in vod 05161 (installation of the allation of the Doty Nickers mode pam tiraircraft post- Ram Air Turbine).
NOTE: Operators have to distinguish the Ram Air Turbine (RAT) Module from the RAT Turbine Assembly sub-assembly.
2. REFERENCED DOCUMENTATION REF 1:CMM 29-21-21, IPL Fig. 3, Item 20.
REF 2:AMM 29-25-00 PB 501 'Functional Test of RAT" (MPD Task 292500-01-1) REF 3:Hamilton Sundstrand Service Bulletin 732365-29-7 REF 4:AMM 29-25-00 PB 301"Extension of the RAT on the Ground" REF 5:AMM 29-25-37 PB 401 "Removal of the RAT Turbine Assembly" REF 7:AMM 29-25-00 PB 301 "Retraction of the RAT on Ground Assembly" REF 6:AMM 29-25-37 PB 401 Installation of the RAT Turbine
3. REASON
3.1 FACTS Hamilton Sundstrand has discovered that some RAT were manufactured with non-conforming screws, Ret. 1 Hamilton Sundstrand CMM. The purpose of these screws is to attach the balance washers, which can have a round or a ectangular shape depending on RAT contiquration. To date there have beer five instances of a fractured screw on various RAT part number contigurations. In one case, the balance washer was also tound missing.
Inspection of other screws in Hamilton Sundstrand stock revealec metallographic non-conformities consistent with those of the fractured screws. The suspect screws have been isolated to one batch from a specific Analysis shows the non-conformity can be a result of the supplier's brittle fracture. applied heat treatment process, which can increase susceptibility to
3.2 CONSEQUENCES The applied heat treatment has resulted in a non-conforming screw material. The affected screws are exposed to potential fracture, with subsequent detachment or insecurity of the associated balance washer.
Detachment of the balance washer can create an unacceptable turbine imbalance.
3.3 AIM The aim of this AOT is to:
- Inform all A300-600 operators of the discovered nonconforming RAT balance washer screws, Page 1
- Provide operators with a procedure to check the suspect Part Numbers and Serial Numbers of In-Service/Spare RAT Turbine Assemblies, and to replace the screws when affected,
- Provide operators with recommendations prior to any RAT ground test as per Ref.2.
4. SHORT TERM ACTION
4.1 PLANNING AND MANPOWER Airbus recommend that the actions described in paragraph 4.2. of this AOT carried out at the next convenient opportunity in accordance with the Following :
4.1.1 Identification of suspect RAT From the list of RAT Turbine Assembly Serial Numbers (S/N) provided in Hamilton-Sundstrand SB Ref. 3, operators must identify the RAT that are in the suspect batch.
be to sed suspect aid inspected in ride with the test ins provided in this AOT paragraph 4.2.
4.1.2 Inspection/replacement following tid scale the actions described in paragraph 4.25 thin the For RAT Turbine Assemblies included in the
- within the next 1500 flight hours after receipt of this All operators Telex, or
- within the next 9 months after receipt of this All Operators Telex, or
- before carrying out a RAT ground test as per Ref.2.
whichever occurs first.
Any RAT Turbine Assembly with a missing screw and/or a missing balance washer during the inspection must be reworked immediately as per paragraph
4.1.3 MANPOWER when screws are found in place on the turbine, Airbus estimate that a maximum of 2 man-hours Assembly. identify Hamilton Sundstrand SB Ref.3 accomplishment on the RAT Turbine are required to gain access, replace the screws and For a RAT Turbine Assembly with a missing balance washer, or with a screw that cannot be completely removed, removal of the RAT Turbine Assembly from the aircraft is required. In this case, a maximum of 6 man-hours are required for replacement of the RAT Turbine Assembly and test on wing.
4.2 DESCRIPTION OF TASK
4.2.1. INSPECTION AND REPLACEMENT OF BALANCE SCREWS ON AIRCRAFT
1. Extend the Ram Air Turbine (RAT) as per Ref. 4 AMM Task.
2. open, safety and tag these circuit breakers:
PANEL DESIGNATION FIN LOCATION Page 2
133vU ACCU PRESS/CTL&/CARGO DOOR/PUMP 7GX 333/T51 133VU PTU CTL/G/Y 6GL 332/U60
3. If the RAT Turbine Assembly Serial Number is not listed in the effectivity of the Ref. 3 Hamilton Sundstrand Service Bulletin:
a) No further action on the RAT is required. Go to paragraph
4.2.1. (6).
effectivity of Ref. 3 Hamilton If the RAT Turbine Assembly Serial Number is listed in the the RAT Turbine Assembly nameplate bears the symbol
a) The Ref. 3 Hamilton Sundstrand Service Bulletin has already been applied. No further action on the RAT is required. Go to paragraph 4.2.1. (6).
"29-7": and the RAT Turbine Assembly nameplate does not bear the symbol the effectivity of Ref. 3 Hamilton Sundstrand Service Bulletin, If the installed RAT Turbine Assembly Serial Number is listed in
a) If all the balance screws are fitted on the turbine. within the timescale given in paragraph 4.1.2.:
3 am ton sunstrand service suffet accordance with the ref.
- Replace the RAT Turbine Assembly (Refer to Ref. 5 and Ref. 6 AMM Tasks) and the affected RAT Turbine Assembly to the vendor for application of Ref. 3 Hamilton Sundstrand Service Bulletin.
b) If one or several screws are sheared/missing and the associated balance washers are still fitted on the turbine.
Before the next flight:
- with the RAT installed on aircraft, replace all the balance on the RAT Turbine Assembly in accordance with the Ret.
3 Hamilton Sundstrand Service Bulletin.
- Replace the RAT Turbine Assembly (Refer to Ref. 5 and Ref. 6 AMM Tasks) and the affected RAT Turbine Assembly to the vendor for application of Ref. 3 Hamilton Sundstrand Service Bulletin.
c) If one or several screws are fractured and balance washers are missing, then before next flight:
- Replace the RAT Turbine Assembly (Refer to Ref. 5 and Ref. 6 AMM Tasks) and send the affected RAT Turbine Assembly to the vendor to balance the turbine assembly and apply the Ref. 3 Hamilton Sundstrand Service Bulletin.
Remove the safety clip(s) and tag(s) and close these circuit breakers:
PANEL DESIGNATION FIN LOCATION 133VU ACCU PRESS/CTL&/CARGO DOOR/PUMP 7GX 333/T51 133VU PTU CTL/G/Y 6GL 332/U60
7. Retract the Ram Air Turbine (RAT) as per Ref. 7 AMM Task.
8 . Report all inspection results to Airbus in accordance with paragraph 7 of this AOT.
4.2.2. INSPECTION AND REPLACEMENT OF SCREWS ON SPARE RAT the Ref. 3 Hamilton Service Allis in If the RAT Turbine Assembly is not listed in the effectivity of
- No further action on the RAT is required. Go to paragraph
4.2.2. (4).
3 Hamilton Sundstrand Service Bulletin, If the RAT Turbine Assembly is listed in the effectivity of Ref. and the RAT Turbine Assembly nameplate bears the symbol "29-7":
- The Ret. 3 Hamilton Sundstrand Service Bulletin has already been applied. No further action on the RAT is required. Go to paragraph 4.2.2. (4).
If the RAT Turbine Assembly is listed in the effectivity of Ref.
3 Hamilton Service Bulletin, and the RAT Turbine Assembly nameplate does not bear the symbol "29-7":
- Replace the screws on the RAT Turbine Assembly in accordance with the Ref. 3 Hamilton Service Bulletin.
- Send the affected RAT Turbine Assembly to the vendor for application of Ref. 3 Hamilton Service Bulletin.
Report all inspection results to Airbus in accordance with paragraph 7 of this AOT.
4.3 MATERIAL / TOOLING The material necessary for this inspection is listed in the Ref. 3 Hamilton Sundstrand Service Bulletin.
Hamilton sundstrand will provide screws free of charge to the affected operators.
The number of screws required for this inspection may vary from operator to operator. Therefore, in order to determine the number of screws to be ordered, operators are requested to contact their assigned Hamilton Sundstrand Commercial Spares Administrator (or fax to +1-815-226-2624, if the responsible Administrator is not known). In addition, operators can "Customer Service" also use the Hamilton Sundstrand website at www.hamiltonsundstrand.com to contact the Commercial followed by _Spares group. Upon entering the website, select "Commercial Spares for other contact and order processing options that are available.
5. FURTHER ACTION No further action is requested after full accomplishment of this AOT.
6. AOT APPROVAL The technical content of this AOT has been approved under the authority of EASA design organisation approval number EASA.21.J.031.
It is anticipated that this AOT will be rendered mandatory by an EASA Airworthiness Directive (AD).
7. REPORTING / ACKNOWLEDGMENT Operators are requested to acknowledge receipt of this AOT within 48 hours after receipt to:
Mr. R. LASCOURS, SEE, Phone: +33 (0)5 61 93 47 91 Page 4
Fax: +33 (0) 5 61 93 32 73 Mailto: richard.lascours@airbus.com This acknowledgement can be made through the Airbus RCSM when available.
Inspection results and questions about the technical content of this AOT are to be addressed to:
Mr. Adrien TONON Hydraulic Systems, SEEL4 Phone: +33 (0)5 67 19 20 35 Malito: adrien.tonon@airbus.com +33 (0) 5 61 93 32 73 Best regards, E. VAN AELST VICE PRESIDENT A300 PROGRAMME
CUSTOMER SERVICES DIRECTORATE 'If you receive this message via e-mail/internet, we draw your attentior to the fact that it may be monitored and/or intercepted.
Further, whilst airbus has taken reasonable measures to ensure the or implied is given that the contents hereof conform to the originali integrity of this message and its contents, case of any doubt, please retrieve this document from your sita address or the Airbus AOLS system or request that it be retransmitted by fax or Page 5